(5) Remove the Stator Ass'y [31] ([30]) (Fig. 6)
(a) Remove the Controller Package [3]. (Model M 8V2 only)
(b) Loosen and remove the two Tapping Screws D4 x 12 [5] ([3]), and remove the Bearing Bushing [6] ([4]).
(c) Disconnect the Brush Terminals [32] ([31]) of the Stator Ass'y [31] ([30]) from the brush holders.
(d) Lift out the Switch (1P Solder Type) [23] ([21]) from the Housing Ass'y [27] ([26]).
(e) Disconnect the Connectors [11] ([9]) in which the lead wires of the Stator Ass'y [31] ([30]) are connected and
remove the screw on the terminal of the switch.
(f) Loosen and remove the two Hex. Hd. Tapping Screws D5 x 65 [33] ([32]).
(g) With a plastic hammer, gently tap on the lower end of the Housing Ass'y [27] ([26]) (the end where the End
Bracket [46] ([45]) is connected) to loosen and separate the Stator Ass'y [31] ([30]) from the Housing Ass'y
[27] ([26]).
Tapping Screw
D4 x 12 [5] [(3)]
Bearing Bushing
[6] [(4)]
(6) CAUTION:
As these models are specifically designed to ensure that the armature is dynamically balanced, there
is extremely little allowable play or imbalance in comparison with other Hitachi electric power tools.
For this reason, be sure to handle the armature and its associated parts very carefully during
disassembly and reassembly.
Controller
Package [3]
Housing Ass'y
[27] [(26)]
Switch (1P Solder Type)
[23] [(21)]
Fig. 6
--- 8 ---
Brush Terminal
[32] [(31)]
Stator Ass'y
[31] [(30)]
Hex. Hd. Tapping Screw
D5 x 65 [33] [(32)]