c. If audio, I/O, and continuous analog video out connections are
being used, attach them to the appropriate terminals on the
Audio / Triggers / Video terminal block on the camera as
shown in Figure 9.4.
d. If using the continuous analog video output use the IQ76x-AVC
analog video cable adapter (not supplied). Remove the 2.8mm
end of the cable, and strip a 1/4-inch of the insulation exposing
the cable as shown in Figure 9.5.
Attach the leads of the analog video cable to terminal 9 & 10
on the Audio / Trigger / Video terminal in Figure 9.6. If
necessary tin the exposed ends of the analog video cable.
Figure 9.5
e. Carefully feed the connected wires one at a time back through
the pass through hole.
f. Snap the camera assembly into the mounting ring by sliding
one of the removal tabs under the lip of the mounting ring
and firmly pivoting the other two mounting tabs into the
mounting plate. The camera mounting tabs should snap into
place.

10 Camera Positioning, Field-of-View Set-up and Focus

NOTE: Camera positioning, field-of–view and focus set-up can be assisted by connecting an analog test
monitor to the installation / set-up RCA port on the side of the camera.
a. Determine camera pan direction by gripping the camera assembly near the
mounting plate. Carefully pivot the camera to the correct pan position.
b. Open the camera shroud by flipping it down and away from the front of the
camera. The front of the camera is indicated by the lens location.
10
Figure 9.4
Figure 9.6