PROGRAMS AND CONTROl UNIT
5.5 Program flow description
Presented below is the Quick program. If the component test in the service menu is not sufficient to
identify a fault you can run this program and compare the results with the flow description below. If they
are in agreement this indicates a correctly functioning control unit.
Component
Main wash
Drain pump
Inlet valve
Circ. pump
Circ. pump & Combi dispenser 3 sec.
Circ. pump
Circ. pump & Element T-30º/35º
Circ. pump
Circ. pump & Element T-30º/60º
SCS
Drain pump
1st rinse
Inlet valve
Circ. pump
Pause
Circ. pump
Drain pump
Inlet valve
Circ. pump
SCS
Drain pump
Final rinse
Inlet valve
Circ. pump & Element T-0/60º
Circ. pump & Combi dispenser 3 sec.
Circ. pump
Circ. pump & Combi dispenser 60 sec.
Circ. pump
Pause
Drain pump
Fan
18
Time
Comments
6 sec.
25 sec. if the previous program was cancelled
with the Start/Stop button
40/45 sec.
With/without diverter
30 sec.
120 sec.
Eco/Normal temp
180 sec.
Eco/Normal temp
22 sec.
Super Clean System
25 sec.
7 sec.
2 sec.
5 sec.
2 sec.
6 sec.
40/45 sec.
With/without diverter
90 sec.
22 sec.
Super Clean System
25 sec.
40/45 sec.
With/without diverter
Eco/Normal drying
None Eco drying
3 sec.
No Eco drying
No Eco drying
90/60 sec.
Eco/Normal drying
60 sec.
25 sec.
600 sec.
Normal drying