PROGRAMS AND CONTROl UNIT
5.5 Program flow description
Presented below is the Quick program. If the component test in the service menu is not sufficient to
identify a fault you can run this program and compare the results with the flow description below. If they
are in agreement this indicates a correctly functioning control unit.
Component
Main wash
Drainage pump
Inlet valve
Circ. pump
Circ. pump & Combi dispenser sec.
Circ. pump
Circ. pump & Element T-0º/5º
Circ. pump
Circ. pump & Element T-0º/0º
SCS
Drainage pump
1st rinse
Inlet valve
Circ. pump
Pause
Circ. pump
Drainage pump
Inlet valve
Circ. pump
SCS
Drainage pump
Final rinse
Inlet valve
Circ. pump & Element T-0/0º
Circ. pump & Combi dispenser sec.
Circ. pump
Circ. pump & Combi dispenser 0 sec.
Circ. pump
Pause
Drainage pump
Fan
18
Time
Comments
sec.
5 sec. if the previous program was cancelled
with the Start/Stop button
0/5 sec.
With/without diverter
0 sec.
10 sec.
Eco/Normal temp
180 sec.
Eco/Normal temp
sec.
Super Clean System
5 sec.
7 sec.
sec.
5 sec.
sec.
sec.
0/5 sec.
With/without diverter
90 sec.
sec.
Super Clean System
5 sec.
0/5 sec.
With/without diverter
Eco/Normal drying
None Eco drying
sec.
No Eco drying
No Eco drying
90/0 sec.
Eco/Normal drying
0 sec.
5 sec.
00 sec.
Normal drying