Follett Symphony 25CT400A Installation, Operation And Service Manual page 10

Symphony 25 / symphony 50 series ice and water dispensers
Table of Contents

Advertisement

5. If power is to be supplied through counter cut-out, complete steps 6-9. If power is to be supplied through rear
of dispenser, proceed to step 10.
6. Temporarily remove rear access panel (Figs. 4 and 5) from rear of dispenser.
7. Loosen junction box mounting screws. Lift junction box and power cord up until cord and mounting screws
clear notches on rear panel of dispenser. Remove Phillips head screws from right side of junction box.
8. Rotate junction box 90 degrees so that screw holes on right side of junction box align with holes on rear
dispenser panel. Resecure junction box to dispenser using Phillips head screws.
9. Place power cord inside dispenser and replace access panel (Figs. 4, 5) to rear of dispenser.
Note: For dispensers to be installed with utilities connected through rear of dispenser, it may be easier to
make preliminary connections before dispenser is set in place.
10. Apply a thick bead, approximately. 1/4" (6mm) diameter, of NSF listed silicone sealant (Dow-Corning RTV-
732 or equivalent) 1/4" (6mm) inside marked outline of dispenser.
11. Carefully position dispenser on counter.
12. Remove four screws securing splash panel to front of dispenser and gently lay splash panel on counter.
(Water line to solenoid valve can be disconnected from water inlet valve by pushing on ring at end of inlet
fi tting while pulling on tubing.)
13. Secure dispenser to counter with four 3/8" bolts (supplied by others).
14. Smooth excess sealant around outside of dispenser.
15. Run water supply line from back of dispenser through utility knock-out (Figs. 4, 5F) or up through counter
cut-out. Connect water supply line to 3/8" FPT fi tting on (Fig. 3G) utility fl ange at bottom of dispenser.
16. Remove 3/4" drain connection plug from either fi tting at rear of dispenser (Fig. 3L) or internal fi tting
(Fig. 3K), as appropriate. Connect and run a dedicated drain line to wall or fl oor drain. An air break should be
provided.
17. Proceed with either Satellite-fi ll or top-mounted icemaker connection instructions, as appropriate.
Fig. 4 – Rear connections, countertop
models with integral icemakers
3/4" FPT drain
14.75"
(375mm)
access panel
(F) utility connection
knock-out
5.875"
(149mm)
.8"
10.5"
(20mm)
(267mm)
Fig. 5 – Rear connections, countertop
models with Satellite-fi ll icemakers
3/4" FPT drain
10
access panel
(F) utility connection
knock-out
(G) ice transport
tube knock-out
5.875"
(149mm)
.8"
(20mm)
6.375"
(162mm)
10.5"
(267mm)
14.75"
(375mm)