PSC SP400rf Programming Manual page 63

Radio frequency handheld laser scanner
Table of Contents

Advertisement

S
I
ETTING
NTERLEAVED
All interfaces that are shipped with the standard factory configuration are
set to read variable length labels. If you switch from variable to fixed
length labels, the default fixed label lengths are 14 digits and 8 digits.
Follow the steps below to change these defaults. All fixed length settings
for Interleaved 2 of 5 must be an even number.
S
F
ET
IXED
1. Identify the fixed length settings you want to make.
2. Scan the SET label.
3. Scan the Enable First Fixed barcode.
S
F
L
ETTING
IXED
ENGTHS
If you are setting a length less than ten, you must scan a zero first and
then the length digit ( 04, 06, 08).
4. Set the first fixed label length by scanning the correct digits
from the next two pages.
If you need to set a second fixed length, continue with step
five. If you do not need to set a second fixed length scan the
No 2nd Fixed Length on this page and skip to step seven.
5. Scan the Set Second Fixed label.
6. Set the second fixed label length by scanning the correct
digits from this page.
7. Scan the END label to complete the procedure.
S
M
L
ETTING
INIMUM
ABEL
1. Identify the minimum length setting you want to make. The
selectable range is 00 to 48 characters.
2. Scan the SET label.
3. Scan the SET MINIMUM LABEL LENGTH barcode.
If you are setting a length less than ten, you must scan a zero first and
then the length digit ( 04, 05, 09).
4. Set the minimum label length by scanning the correct digits
from the next two pages.
5. Scan the END label.
R44-1027
2
5 F
OF
IXED AND
L
ENGTH
M
L
L
INIMUN
ABEL
ENGTHS
57