Axis Q1615-E User Manual page 11

Hide thumbs Also See for Q1615-E:
Table of Contents

Advertisement

AXIS Q1615-E Network Camera
Hardware Overview
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
To change the iris configuration:
1. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the current configured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
To change the iris configuration for P-iris lenses not listed in the drop-down list:
1. Download the iris configuration file from www.axis.com
2. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the current configured iris type.
3. In Iris configuration: Click Edit.
4. Go to the Upload tab.
5. Click Browse and select the configuration file.
6. Click Upload. The installed iris lens should now be included in the Iris Selection drop-down list.
7. Select the installed iris lens from the drop-down list and click OK.
Note
• If you select a DC iris configuration file for a P-iris lens, an error message will appear below the iris configuration type in the
Camera Settings page. For custom DC Iris lenses, select Generic DC Iris option.
• There is no need to restart the product after changing the lens. However, the product must be restarted if you are
interchanging between a P-iris, DC-Iris or fixed/manual iris lens. In order to set the focus and position the lens, the
product must be connected to the network.
11