Programmable digital thermostat with communication

Advertisement

DPC-1
Programmable digital thermostat
with communication
Versión 2.0
Technical Information
ER-0028/1991
CGM-97/013
E U R O V E N T
CERTIFIED PERFORMANCE
Clima Roca York S.L. is participating in the EUROVENT Certification Program.
Products are as listed in the EUROVENT Directory of Certified Products,
in the program
AC 1, AC2, AC3, LCP and FC .
Ref: Y-R70110 0306
1

Advertisement

Table of Contents
loading

Summary of Contents for York DPC-1

  • Page 1 Ref: Y-R70110 0306 Technical Information E U R O V E N T CERTIFIED PERFORMANCE Clima Roca York S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory of Certified Products, ER-0028/1991 CGM-97/013 AC 1, AC2, AC3, LCP and FC .
  • Page 3: Table Of Contents

    - Programming user profile - Location - Programming comfort temperature set point - Basic elements (occupation or day) - Fastening the thermostat to the wall - Programming economy temperture - Standard electric connections, thermostat DPC-1 set point (stand-by or night) - Temperature table...
  • Page 5: Internal View Of The Thermostat

    Internal view of the thermostat 1 - With the front cover down; normal position. AUTO AUTO PROG °C 0h 2 8 10 12 14 16 18 20 22 24 2 - With the front cover up, showing the front panel. Raise the cover to access the controls only. AUTO AUTO PROG...
  • Page 6: Air Conditioning Modes

    A demand is generated when the room temperature is below Air conditioning modes the programmed set point. Set point is understood as the tem- By pressing the MODE key consecutively, the following air perature we want in the room. conditioning modes can be selected. Auto This mode activates heating as well as cooling operations.
  • Page 7: Vent Only

    for heat pump units also equipped with electric heaters or Configuration with speeds allows choosing between: other auxiliary heating elements. This mode avoids operation - ON: The fan appears and the wind icons indicate the speed. of the compressors in extreme outdoor temperature condi- - AUTO: Operative as needed, upon demand.
  • Page 8: Key Functions

    Key functions If the thermostat is in the AUTO or AUTO PROG mode, in the Setting Mode one of the heat or cool icons only will appear. If Programming key the Setting Mode is accessed with the key, the heat The word PROG is printed on this key.
  • Page 9: Fan Mode Key

    When a status is changed in the time schedule profile, the In the Programming Mode this allows validating the occupation status will go back to the status programmed in changes made. the profile (without flashing), and the icon will disappear. Outdoor temperature key It has the symbol printed on the key itself, and the...
  • Page 10: Clock Setting

    The active keys are: Selection of time schedule profiles Allow selecting the active option (flashing). The forward There are three predefined profiles (P1 to P3), three addi- order of the options will be as previously displayed: tional user-programmable profiles and 6 pro- starting with the clock and finishing with the unoccu- files (P7 to P12) that can be programmed through communi- pied icon.
  • Page 11: Programming User Profile

    Goes on to Programming Menu (back). Goes on to Selection of time schedule profiles (back) without saving. Active only when the profile is displayed on PROG screen. Allows accessing Programming User Profile. Pressing and holding allows recovering the factory PROG programmed default values, and save these values.
  • Page 12: Set Points

    If when moving one of the set points we come to less than icon is displayed without flashing, whereas the , , and one degree from the following set point, it will be "dragged" so icons are flashing. The temperature set point of this mode is as to avoid the unsuitability of the set points.
  • Page 13: Programming Origin Of Temperature Readings

    If the digital probe is selected, S5, S6, S7 and S8 will also The active keys are: appear, depending upon the number of probes installed. Allow changing the selected origin, S-1 to The calibration appears in temperature digits. The maximum S-8.
  • Page 14: Selection Of Outdoor Probe Type

    - C-n: the thermostat is not in communication with the ma- Micro-switches for configuration of the chine. The communication error Er 93 would not be displayed thermostat on screen. The SW1 micro-switches for configuration are inside the ther- The active keys are: mostat, in the back of the front panel.
  • Page 15: Default Parameters

    Micro-switch SW1 allow the configuration of the following pa- Dead battery. The dead battery icon indicates the batteries rameters: are dead, and these should be changed. System configura- - Pin 1: Lock keyboard. In OFF the keyboard is not locked. In tion is not lost when changing the batteries.
  • Page 16: Communication

    Y2 and W are activated successively (in HEAT). Once the temperature reaches the set point, the stages go off. Communication The DPC-1 thermostat operates by communication only. ALKALINE BATTERIES By communication it is possible to monitor the status of the ELECTRIC CONNECTING thermostat, while being able to program same.
  • Page 17: Standard Electric Connections, Thermostat Dpc-1

    1.5 V alkaline batteries at the rear of the front panel, as shown below: Standard electric connections, thermostat DPC-1 (for thermostat with communication) Once the base is fastened to the wall, wire the thermostat as shown in the following illustration: SHIELDED CABLE 2 x 0.5 mm...
  • Page 18: Temperature Table

    DPC-1 and DPC-1R, ambient remote probe (RS-1), ducts Temperature table remote probe (DS-1) and average probe (AS-1). The following table indicates the ratio between the tempera- ture, heater and voltage. Ambient probe 15 K Ohm: Thermo- Current Temperature °C NTC value 0.445...