Specifications; Vent System Approvals; System Components; Dimensions - Quadra-Fire COLUMBIA BAY Installation, Venting, Operation & Maintenance Manual

Direct vent gas insert
Table of Contents

Advertisement

This appliance may only use the Direct Vent Chimney System Required with the Unit
and MUST NOT be connected to a chimney flue servicing a separate Solid Fuel or
Approved vent system terminations are labeled for identification. Two separate 3" diameter listed flexible aluminum or
stainless steel gas vent is used for both exhaust and incoming combustion air and must be run up through the fireplace
chimney and terminated vertically. Horizontal terminations MUST NOT be done. Follow the vent manufacturer's installation
instructions in conjunction with this manual.
Part Number
840-0380
DVIK33
Flex 3302
923GK
980
991
841-0870
841-0880
841-0890
TOP VIEW
25-5/8"
20"
29"
LEFT SIDE
03/28/01 #250-6240
Columbia Bay Direct Vent Gas Insert

SPECIFICATIONS

WARNING!
Gas Burning appliance.

VENT SYSTEM APPROVALS

SYSTEM COMPONENTS

Description
Columbia Bay Direct Vent Gas Fired Insert - Natural Gas (Firebox only)
Flex Kit includes 923K, 991, and Flex 3302.
Flex Kit (Includes (2) 3"x30' Chimney Liner Flex)
3" Direct Vent Chimney Liner Termination Kit (Dura-Vent product)
Vertical Termination Cap with Wind Halo (Dura-Vent product)
High Wind Termination Cap (Dura-Vent product)
Standard Panel Set (28-1/2" x 40")
Medium Panel Set (31" x 44")
Large Panel Set (33" x 46")

DIMENSIONS

10-9/16"
20"
7-3/4"
RIGHT SIDE

MINIMUM FIREBOX OPENING

Height: Front 18"
Width:
Front: 26"
Depth:
Top: 13"
SIDE VIEW
Rocker switch & wiring is
Electrical Connection &
accessible here on LEFT
Gas Connection extend
SIDE when shipped.
here from RIGHT SIDE.
Rear: 15"
Rear:
20"
Bottom: 13"
18"
Page 7