Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
CB1200 PELLET INSERT APPLIANCE
Model: CB1200MI-MBK
CAUTION
Tested and approved for wood pellets and corn pellets.
Burning of any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fire officials or authorities having juris-
diction about restrictions, installation inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
If the information in these instruc-
tions is not followed exactly, a
fire could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over fire - If appliance or chimney
connector glows, you are over firing. Over
firing will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause house fire.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other flammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafire.com
7014-285A
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
October 9, 2017

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire CB1200MI-MBK

  • Page 1 CB1200 PELLET INSERT APPLIANCE tions is not followed exactly, a fire could result causing property Model: CB1200MI-MBK damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CB1200 Pellet Insert Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • •...
  • Page 3: Important Safety Information

    ASTM E1509-95, UL127, ULC S628-93, ULC S610-M87, ULC/ ORD-C-1482-M1990, (UM) 84-HUD WARNING The Quadra-Fire CB1200 Pellet Insert meets the U.S. Envi- ronmental Protection Agency’s emission limits for pellet Fire Risk. inserts sold after May 15, 2015.
  • Page 4: Getting Started

    CB1200 Pellet Insert Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Thermostat Wall Control Location

    CB1200 Pellet Insert B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. Fire Risk. • Maximum wire length from appliance is 100 feet (30.48m) Damaged parts could impair safe operation. Do continuous non-spliced wire.
  • Page 6: Install Checklist

    CB1200 Pellet Insert E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: __________________________________________________________________________ Date Installed: __________________________________________________________________________ Lot/Address: __________________________________________________________________________ Location of Appliance: ______________________________________________________________...
  • Page 7: Dimensions And Clearances

    CB1200 Pellet Insert Dimensions and Clearances A. Appliance Dimensions 29-1/4 in [743mm] 22 in [559mm] 29-1/4 in [743mm] 8-3/4 in [223mm] 22 in [559mm] 8-3/4 in [223mm] 12-3/8 in 13 in [315mm] 10-7/8 in [330mm] 12-3/8 in [277mm] 13 in [315mm] 10-7/8 in [330mm]...
  • Page 8: B. Clearance To Combustibles, Ul And Ulc 8

    Part 811-0730, allow 1-1/2 inches (38mm). Figure 8.1 NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert appliance must be supplied in addition to this part.
  • Page 9: Minimum Opening For Masonry & Zero Clearance Fireplaces

    CB1200 Pellet Insert C. Minimum Opening for Masonry & Zero Clearance Fireplaces TOP TRIM 19-3/4 in 19-3/4 in (502mm) (502m) 28-1/2 in (724mm) 18-1/4 in HEARTH (464mm) EXTENSION Figure 9.3 Figure 9.1 (406mm) Note: If trim measurement is over 3/4 in (19mm) in depth EXTENSION use mantle or side clearances to combustibles.
  • Page 10: Floor Protection

    8 inches (203mm) to each side of the door open- ing. * See Thermal Resistance: R value. NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert appliance must be supplied in addition to this part.
  • Page 11: Installation Into A Factory-Built Fireplace

    CB1200 Pellet Insert F. Installation into a Factory-Built Fireplace The following is only one example as there are many differ- ent models of factory-built fireplaces. The following modifications are permissible: NOTE: This example is for reference only. Any modifica- • Removal of damper or locked in open position tions must not compromise the structural integrity •...
  • Page 12: Installation Into A Masonry Fireplace

    CB1200 Pellet Insert H. Prefabricated Metal Chimney Example Removal of Factory-Built Fireplace Cont. The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements: • Must be minimum 6 inch (152mm) inside diameter of Keep sharp edge of high temperature chimney listed to UL 103 HT (2100 metal floor away from...
  • Page 13: Vent Information

    CB1200 Pellet Insert Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 13.1 Termination Cap Restricted Area Air Supply Inlet Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 14: Avoiding Smoke And Odors

    CB1200 Pellet Insert B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent con- Negative Pressure, Shut-Down and Electrical Power figuration the frequency of power outages should be consid- Failure ered: To reduce the probability of back-drafting or burn-back in •...
  • Page 15: Negative Pressure

    Avoid installing the appliance near doors, walkways or (76-152mm) Top Vent Offset Adapter, use Listed double wall small isolated spaces flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. • Recessed lighting should be a “sealed can” design 3.
  • Page 16: Equivalent Feet Of Pipe

    CB1200 Pellet Insert F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched. Non-combustible shielding or guards Figure 16.1.
  • Page 17: Venting Systems

    CB1200 Pellet Insert Venting Systems WARNING A. Full Reline With Outside Air - Horizontal Fire Risk. Inspection of Chimney: CAUTION • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 Never draw outside combustion air from: •...
  • Page 18: Full Reline With Outside Air - Vertical

    CB1200 Pellet Insert B. Full Reline With Outside Air - Vertical NOTE: In Canada only a full reline is allowed per ULC NOTE: Check clearances carefully for this type of S628, ORD ULC C1482-M1990. installation to ensure adequate room for outside air venting.
  • Page 19: Appliance Set-Up

    CB1200 Pellet Insert Appliance Set-Up Using a Phillips head screwdriver and two A. Rear Shroud Installation screws to attach Filler Bracket (Figure 19.3) Tools Required: Electric drill, #26 drill bit, Phillips screw driver, 3/8 inch wrench, and 7/16 inch socket wrench. Needed to complete installation of the Rear Shroud Assembly;...
  • Page 20 CB1200 Pellet Insert 4. Install the left shroud panel corner; 2 screws into 8. Assemble the right shroud panel corner and the right back of hopper and 1 screw down into the filler piece shroud panel using 3 screws (Figure 20.5). (Figure 20.1).
  • Page 21: Outside Air Kit Instructions

    Add two screws to NOTE: A Quadra-Fire outside air kit; 811-0872, is available through your Quadra-Fire Dealer to be used as a the out- secure shroud assembly to the appliance (Figure side air option, but is required for mobile home installations.
  • Page 22: Adjustable Hopper Options

    CB1200 Pellet Insert C. Adjustable Hopper Options E. Adjustable Hearth Support Depending on your installation, the hopper can be adjusted Size: 9”D x 45”W, 2” to 10” Height Adjustment down 2-1/2 inches (64mm) and will decrease in capacity from 75lbs to 60lbs. Included in Kit: (1) trim top, (1) trim front, (2) trim sides, double-sided tape (already installed) To adjust hopper:...
  • Page 23: Panel And Trim Set

    CB1200 Pellet Insert F. Panel and Trim Set EXPLODED VIEW OF SCISSORS Standard Size: 30 inches H x 40 inches W (762mm x 1016mm) Large Size: 33 inches H x 50 inches W (838mm x SCREWS ARE CIRCLED 1270mm) Included in Kit: 2 side panels, 1 top panel, 2 side trim, 1 top trim, 2 corner brackets and fastener package.
  • Page 24 CB1200 Pellet Insert F. Panel and Trim Set (Cont’d) 5. Hold side curtains in open position and lower panel set over insert setting lower edge of top panel in slot between hopper lid and panel support as shown in Figure 24.5. Place existing screw head (installed in Figure 24.6) into locater hole in floor of insert.
  • Page 25: Thermostat Installation And Operation

    CB1200 Pellet Insert G. Thermostat Installation and Operation Open right side plane to access a 4 screw terminal block located on the bottom right hand side next to the power cord inlet. The center 2 screws are for the thermostat wires.
  • Page 26: Optional Log Set Placement Instructions

    CB1200 Pellet Insert H. Optional Log Set Placement Instructions CAUTION Terminal Block Center 2 Screws for Logs are FRAGILE. Use extreme care when handling or Thermostat Wires cleaning logs. Place the front log in first as shown in Figure 26.5 charred area surrounding fire pot.
  • Page 27: Mobile Home Installation

    Joist Shield/Firestop Double Wall Connector Pipe Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24. NOTE: A Quadra-Fire outside air kit; 811-0872, is available through your Quadra-Fire Dealer. Figure 27.1 WARNING CAUTION Products of combustion generate carbon monoxide and different fuels generate different levels.
  • Page 28: Reference Materials

    CB1200 Pellet Insert Reference Materials A. Service & Maintenance List Date of Service Performed By Description of Service 7014-285A October 9, 2017...
  • Page 29 CB1200 Pellet Insert Date of Service Performed By Description of Service October 9, 2017 7014-285A...
  • Page 30: Accessory List

    CB1200 Pellet Insert B. Accessory List CB1200MI-MBK Service Parts Beginning Manufacturing Date: June 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 31 CB1200 Pellet Insert CB1200MI-MBK Service Parts Beginning Manufacturing Date: June 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 32 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents