Checking The Static And Supply Pressure - Viessmann Vitodens 200-W Installation Instructions Manual

45 and 60 kw wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Further details regarding the individual steps
Yes
Automatic calibra-
tion of the com-
bustion controller
For further details regarding faults, see
page 115.

Checking the static and supply pressure

Danger
CO formation as a result of incor-
rect burner adjustment can have
serious health implications.
Check the CO content before and
after carrying out work on gas
appliances.
38
Fault E3
No
Fault Eb
(cont.)
Operation with LPG
Purge the LPG tank twice during com-
missioning or replacement. Vent the tank
and gas connection line thoroughly after
purging.
Ensure adequate
heat transfer.
Press reset button
R.
Check gap be-
tween ionisation
electrode and
burner gauze as-
sembly.
Check allocation of
gas type (coding
address 82, gas
train setting).
Check flue system;
remedy flue gas re-
circulation if re-
quired.
Press reset button
R.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w b2ha-45Vitodens 200-w b2ha-60

Table of Contents