Viessmann Vitodens 200-W Installation Instructions Manual page 129

45 and 60 kw wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Fault codes
(cont.)
Dis-
Const.
played
fault
code
EA
X
Eb
X
EC
X
Weath.-
System char-
comp.
acteristics
X
Burner in a fault
state
X
Burner in a fault
state
X
Burner in a fault
state
Troubleshooting
Cause
Measures
Ionisation
Check flue system;
current out-
remedy flue gas re-
side permissi-
circulation if re-
ble range dur-
quired.
ing calibration
In open flue opera-
(excessive
tion, prevent high
deviation
incidence of dust in
from previous
the combustion
level)
air.
Press reset button
R.
Following several
unsuccessful reset
attempts, replace
the coding card
and press reset
button R.
Repeated
Check gap be-
flame loss
tween ionisation
during cali-
electrode and
bration
burner gauze as-
sembly (see
page 46).
Check allocation of
gas type (see
page 36).
Check flue system;
remedy flue gas re-
circulation if re-
quired.
Press reset button
R.
Parameter
Press reset button
fault during
R
calibration
or
Replace coding
card and then
press reset button
R.
129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w b2ha-45Vitodens 200-w b2ha-60

Table of Contents