Self-Diagnosis System Information; Main Menu - Mace MVC-PTZ-23X Product Manual

Sq series indoor/outdoor 23× ptz speed dome camera
Table of Contents

Advertisement

Please make sure all the cable connections are right.

4.2 Self-diagnosis System Information

After installation, please connect speed dome to power. The system goes on a self-diagnosis,
and then it pops up the above interface to show the system information.
If there is anything wrong during the self-diagnosis, system pops up error code.
The above interface disappears after speed dome received the first command (or the display
time lasts for 4 minutes.)
ADDR: Here you can view dome address information. For example, 001-H, 1 is the address
number, -H is hard address mode. –S is software address mode.
Baud rate: Dome communication baud rate.
Parity: Communication parity bit format.
Protocol: Current communication protocol.
Model: Dome type.
Temperature: Current dome internal temperature.
Software: Dome PTZ software version.

4.3 Main Menu

You can open the IP dome menu via control keyboard, matrix, or speed dome control terminal.
SYSTEM INFORMATION:Dome self-diagnosis information, address information, system
time setup, set north direction, language, factory default setup, reboot and so on.
DISPLAY INFORMATION: Display dome preset title, azimuth display, time, direction, dome
internal temperature, dome external temperature information.
CAMERA PARAMETERS:Display dome white balance setup, exposure setup, day/night
setup, focus setup.
FUNCTION SETTING : Set preset, pan, scan, auto cruise, pattern, idle motion, time task
and privacy mask function.
ALARM SETTING
out, reset delay, save setup and etc.
ADDR
BAUD RATE
PARITY
PROTOCOL
MODEL
TEMP
SOFTWARE
BACK
EXIT
SYSTEM INFORMATION
DISPLAY SETTING
CAMERA SETTING
FUNCTION SETTING
ALARM SETTING
EXIT
:Set dome alarm number, action, contact, preset, scan, cruise, replay
:001-H
:9600
:NONE
:PELCO-P
:SD66XX
: 032℃
:V1.00