TEST PROGRAM

No.
A
Starting test program
B
Normal testing procedure & testing procedure in case of NG
C
Testing procedure when judged as NG
1
System RAM test
2
RAM battery check
3
Power battery check
4
LCD test
5
LED test
6
Panel switch test
7
MIDI IN/OUT test
8
Host select test
9
To host test
10
Wave ROM test
11
OUTPUT (L) sound output test
12
OUTPUT (R) sound output test
13
Smart Media test
14
Style ROM test
15
Effect RAM L test
16
Effect RAM R test
17
Foot switch test
18
Factory set
19
EXIT
Note) OUTPUT (L) and OUTPUT (R) may be represented as L and R respectively.
Item
Judgment conditions, etc.
OK/NG
OK/NG
OK/NG
1 dot interval vertical stripe inverted blinking
Red, green
ON/OFF
Data AA EF 00 55
OK/NG
Factory inspection item
OK/NG
OUTPUT(L) 880Hz±3Hz Load 33ohm
1.0% or less. Load 33ohm
OUTPUT(R) 880Hz±3Hz Load 33ohm
1.0% or less. Load 33ohm
OK/NG
OK/NG
INPUT -35±0.5dBm(Ro=600ohm)
OUTPUT(L) 0±3dBm Load 33ohm
1.0% or less. Load 33ohm
OUTPUT(R) -50dBm or less. Load 33ohm
INPUT -35±0.5dBm(Ro=600ohm)
OUTPUT(R) 0±3dBm Load 33ohm
1.0% or less. Load 33ohm
OUTPUT(L)-50dBm or less. Load 33ohm
Peak LED
INPUT -25±1dBm(Ro=600ohm) Light up
OK/NG
*Noise level
OUTPUT(L), OUTPUT(R)
-80dBm or less. Load 33ohm