4-6 METER ADJUSTMENTS
ADJUSTMENT
ADJUSTMENT CONDITION
ENTERING
1 • Enter the adjustment mode:
q Turn power OFF.
ADJUSTMENT
w Terminate the [REMOTE] jack
MODE
with a 3.5(d) mm mini-plug.
e While pushing [SSB] and [CW/
RTTY], turn power ON.
CAUTION:
NEVER
matically transmits when transmit item in the [F-2 (TX)] is selected.
METER
1 • Push [F-1 (METER)] to enter the
SCALE
meter scale adjustment.
2
3
4
5
6
7
8
TX METER
1
• Push [F-2 (METER)] to enter the TX
(HF POWER
meter scale adjustment.
METER)
• Connect an RF power to [ANT1]
2
connector.
• Connect a 100 Ω dummy load to
[ANT2] connector.
• Connect audio generator to [MIC]
connector and set as:
3
FREQUENCY : 1.5 kHz
LEVEL
4
5
6
select adjustment items [F-2 (TX)] while transceiver is connected to an SSG. Because transceiver auto-
: 10mVrms
DISPLAY
ADJUST MODE
Push [F-1 (METER)], [F-2 (TX)] or [F-3 (RX)] to
select each adjustment mode.
Once entering adjustment mode, use [F-1
(
opening display.
Set the analog meter to S1 position using the
-- METER --
tuning dial. Then push [F-5 (SET)] to store the
SCALE S1
"S1" meter into memory, and go to the next step.
-- METER --
Set the analog meter to S3 position using the
tuning dial. Then push [F-5 (SET)] to store the
SCALE S3
"S3" meter into memory, and go to the next step.
-- METER --
Set the analog meter to S5 position using the
tuning dial. Then push [F-5 (SET)] to store the
SCALE S5
"S5" meter into memory, and go to the next step.
Set the analog meter to S7 position using the
-- METER --
tuning dial. Then push [F-5 (SET)] to store the
SCALE S7
"S7" meter into memory, and go to the next step.
Set the analog meter to S9 position using the
-- METER --
tuning dial. Then push [F-5 (SET)] to store the
SCALE S9
"S9" meter into memory, and go to the next step.
-- METER --
Set the analog meter to S9+20 position using
the tuning dial. Then push [F-5 (SET)] to store
POWER S+20
the "S9+20" meter into memory, and go to the
next step.
-- METER --
Set the analog meter to S9+40 position using
the tuning dial. Then push [F-5 (SET)] to store
POWER S9+40
the "S9+40" meter into memory, and go to the
next step.
-- METER --
Set the analog meter to S9+60 position using
the tuning dial. Then push [F-5 (SET)] to store
SCALE S9+60
the "S9+60" meter into memory, and retuns to
the opening display.
-- TX --
Push [F-5 (SET)] to store the "POWER 0%"
meter into memory, and go to the next step.
POWER 0%
-- TX --
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
POWER HF Tuner
"POWER HF Tuner" meter into memory, and
go to the next step.
-- TX --
Set the output power to 10 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
POWER HF 10%
"POWER HF 10%" meter into memory, and go
to the next step.
-- TX --
Set the output power to 25 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
POWER HF 25%
"POWER HF 25%" meter into memory, and go
to the next step.
-- TX --
Set the output power to 50 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
POWER HF 50%
"POWER HF 50%" meter into memory, and go
to the next step.
-- TX --
Set the output power to 104 W using the tun-
ing dial. Then push [F-5 (SET)] to store the
POWER HF 100%
"POWER HF 100%" meter into memory, and
go to the next step.
4 - 13
OPERATION
)] to skip items, or [F-2 (EXIT)] to return the