Boring A Wall Hole And Installing Wall Embedded Pipe; Installing Indoor Unit - Daikin FTXS50FV1B Installation Manual

R410a split series
Hide thumbs Also See for FTXS50FV1B:
Table of Contents

Advertisement

2.

Boring a wall hole and installing wall embedded pipe.

• For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent possible
heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 80mm in the wall so it has a down slope
toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
3.

Installing indoor unit.

3-1. Right-Side, Right-Back, or Right-Bottom Piping
1) Attach the drain hose to the underside of the refrigerant pipes with
adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with insulation
tape.
3) Pass the drain hose and refrigerant pipes through the wall hole,
then set the indoor unit on the mounting plate hooks by using the
markings at the top of the indoor unit as a guide.
4) Open the front panel, then open the service lid.
(Refer to Installation tips.)
5) Pass the interconnecting wires from the outdoor unit through the
feed-through wall hole and then through the back of the indoor
unit. Pull them through the front side. Bend the ends of tie wires
upward in advance for easier work. (If the interconnecting wire
ends are to be stripped first, bundle wire ends with adhesive
tape.)
6) Press the indoor unit's bottom panel with both hands to set it on
the mounting plate hooks. Make sure the wires do not catch on
the edge of the indoor unit.
■English
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Remove pipe port cover
here for right-side piping
Right-bottom
piping
Remove pipe port cover
here for right-bottom piping
A
Mounting plate
Hang indoor unit's hook here.
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Outside
Caulking
Wall embedded pipe
(Field supply)
Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.
A
Mounting plate
Interconnecting
wires
6