Indoor Unit Installation

1.

Installing the mounting plate.

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
60
* The removed pipe port cover can be
2.

Boring a wall hole and installing wall embedded pipe.

• For walls containing metal frame or metal board, be sure to use a wall embed-
ded pipe and wall cover in the feed-through hole to prevent possible heat,
electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 65 mm in the wall so it has a down slope
toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
IEnglish
(Bolt size : M10)
Recommended mounting-plate
105
retention spots (6 spots in all)
65
269
Through-the-wall
hole ø65mm
Drain hose position
kept in the mounting plate pocket
Leveling mounting plate
Dangle a weighted thread
a
and align thread with
vertical arrow.
Place a leveler
b
on raised tab.
(Bolt size : M10)
Gas pipe end
50
Liquid pipe end
784
Removed pipe
port cover
A
Mounting plate
Use tape measure
as shown.
Position the end of
tape measure at ∇
95
Unit outline
85
110
(unit: mm)
Inside
Outside
Wall embedded pipe
(field supply)
Caulking
Wall hole cover
(field supply)
Wall embedded pipe
(field supply)