Counter Balance Spring Adjustment; Installation Procedure - Viking Professional & Designer 450 Series Installation Manual

Built-in dishwashers
Hide thumbs Also See for Professional & Designer 450 Series:
Table of Contents

Advertisement

Counter Balance Spring Adjustment - If Necessary
a
Disconnect cable from hook.
c
Reconnect cable to hook.
14
b
Increase
tension
Decrease
tension
Set counter balance spring connector in appropriate
location.
NOTE: For custom panel
installation the door may
require adjustment to the
preload of the counterbalance
springs. Follow these steps to
adjust the tension.

Installation Procedure

1
Using tie strap attached to dishwasher, band water line,
Carefully lay dishwasher on its back and attach the kick
plate brackets. Screws for the brackets will already be
in the base. NOTE: Be careful not to pinch hoses or
power cord beneath dishwasher.
3
Position unit in front of cutout.
Slide unit into opening; be sure to feed water, electrical
5
Equal distance
Up
Down
Using a level, adjust to appropriate height. Left and right
adjust side to side and center adjusts front to back.
15
2
drain line, and power cord together.
4
and discharge lines into adjacent cabinet.
6
To check level, front to back, pull the top rack half-way
out of unit. The rack should remain stationary and not
move in or out.