HIGH ALTITUDE INSTALLATIONS

RGFE/RGGE/RGJF -HIGH
ALTITUDE CONVERSION
WARNING
FOR RGGE-06 AND RGJF-06 MOD-
ELS, A PRESSURE SWITCH CHANGE
IS NOT NECESSARY AT ANY ELEVA-
TION. FOR RGGE-07 & RGJF-07 MOD-
ELS, A PRESSURE SWITCH CHANGE
IS REQUIRED AT ELEVATIONS
ABOVE 8,000 FT. FOR ALL OTHER
RGFE/RGGE/RGJF FURNACES, A
PRESSURE SWITCH CHANGE IS
REQUIRED AT ELEVATIONS ABOVE
5,000 FT. THE APPROPRIATE HIGH-
ELEVATION KIT WILL CONVERT THE
FURNACE FOR USE ABOVE THE
APPROPRIATE ELEVATION STATED
HERE. DO NOT INSTALL THE -278
OPTION FURNACE OR THE HIGH
ALTITUDE KIT BELOW THE STATED
ELEVATION. DOING SO CAN CAUSE
SERIOUS PERSONAL INJURY OR
DEATH OR EQUIPMENT FAILURE.
HIGH ALTITUDE CONVERSION
KITS
WARNING
FOR RGGE-06 & RGJF-06 MODELS, A
PRESSURE SWITCH CHANGE IS NOT
NECESSARY AT ANY ELEVATION.
FOR RGGE-07 & RGJF-07 MODELS, A
PRESSURE SWITCH CHANGE IS
REQUIRED AT ELEVATIONS ABOVE
8,000 FT. FOR ALL OTHER
RGFE/RGGE/RGJF FURNACES, A
PRESSURE SWITCH CHANGE IS
REQUIRED AT ELEVATIONS ABOVE
5,000 FT. THE APPROPRIATE HIGH-
ELEVATION KIT WILL CONVERT THE
FURNACE FOR USE ABOVE THE
ELEVATION STATED HERE. DO NOT
INSTALL THE HIGH ALTITUDE KIT
BELOW THE STATED ELEVATION.
DOING SO CAN CAUSE SERIOUS
PERSONAL INJURY OR DEATH OR
EQUIPMENT FAILURE.
HIGH ALTITUDE FIELD
CONVERSION KITS (RGFE MODELS)
MODEL
INPUT(BTU)
RGFE-06XXXXX
60,000
RGFE-07XXXXX
75,000
RGFE-09XXXXX
90,000
RGFE-10XXXXX
105,000
RGFE-12XXXXX
120,000
HIGH ALTITUDE FIELD
CONVERSION KITS (RGGE & RGJF
MODELS)
MODEL
RGGE OR RGJF-06XXXXX
RGGE OR RGJF-07XXXXX
RGGE OR RGJF-09XXXXX
RGGE OR RGJF-10XXXXX
RGGE OR RGJF-12XXXXX
Orifice Selection for High Altitude
Applications
Natural Gas
CAUTION
INSTALLATION OF THIS FURNACE
AT ALTITUDES ABOVE 2000 FT (610
m) SHALL BE IN ACCORDANCE
WITH LOCAL CODES OR, IN THE
ABSENCE OF LOCAL CODES, THE
NATIONAL FUEL GAS CODE, ANSI
Z223.1/NFPA 54 OR NATIONAL
STANDARD OF CANADA, NATURAL
GAS AND PROPANE INSTALLATION
CODE, CAN B149.1.
INSTALLATION OF THIS APPLIANCE
AT OR ABOVE 5000 FT (1525 m)
SHALL BE MADE IN ACCORDANCE
WITH THE LISTED HIGH ALTITUDE
CONVERSION KIT AVAILABLE FOR
THIS FURNACE.
34" 90 Plus furnaces installed at high
elevations require the installation of a
high altitude kit for proper operation.
The high altitude kit consists of a high
altitude pressure switch that replaces
the high pressure switch of the furnace.
The pressure switch must be installed
at elevations above those listed.
Elevations above 2000 ft. require the
furnace to be de-rated 4% per thou-
sand feet. NOTE: Factory installed ori-
fices are calculated and sized based on
a sea level Natural Gas heating value
of 1075 BTU per cubic ft. Regional
reduced heating values may nullify the
need to change orifices except at
extreme altitudes. Table 10 shows
some quick conversions based on ele-
vation and gas heating value. This table
is combined and simplified from Tables
F1 and F4 of the National Fuel Gas
KIT NO.
Code.
RXGY-F34
RXGY-F35
RXGY-F36
RXGY-F37
RXGY-F38
TABLE 10
Natural Gas Orifice Drill Size (4% per 1000 ft. De-Rate)
IMPORTANT: For 90+ Furnaces only. Do not use this chart for any 80+ Furnace.
Burner Input (per burner) 15,000 BTU @ Sea Level
Annual Avg. Heat
Value (btu per ft
3
850
900
1000
1075
1170
INPUT(BTU)
KIT NO.
60,000
No Kit
Required
75,000
RXGY-F23
(8000 ft and
above only)
90,000
RXGY-F24
105,000
RXGY-F25
120,000
RXGY-F26
Sea level 2000 to 3000 to
4000 to
)
to 1999 ft 2999 ft
3999 ft
4999 ft
47
48
48
49
48
49
49
49
49
50
50
50
50
51
51
51
51
51
52
52
EXAMPLES
The following are examples of orifice
sizing using the National Fuel Gas
Code Appendix F. For a simplified
estimation of orifice size based on
heating value and elevation use
Tables 10 and 11. However, calcula-
tions are the best method.
Example: 900 BTU/ft
Regional
3
Natural Gas Heating Value
I / H = Q
15000 / 900 = 16.68 ft
/hr
3
I = Sea Level input (per burner):
15000
H = Sea Level Heating Value: 900
Q = 16.68 ft
Natural Gas per hour.
3
From Table F.1 of National Fuel Gas
Code Handbook, 2002 (3.5 w.c. col-
umn)
Orifice required at Sea Level: # 48
From Table F.4 of National fuel Gas
Code Handbook, 2002
Orifice required at 5000 ft. elevation
(4% de-rate per thousand ft): # 50
Orifice required at 8000 ft. elevation
(4% de-rate per thousand ft): # 51
Example: 1050 BTU/ft
Regional
3
Natural Gas Heating Value
I / H = Q
15000 / 1050 = 14.63 ft
/hr
3
I = Sea Level input (per burner):
15000
H = Sea Level Heating Value: 1050
Q= 14.28 ft
Natural Gas.
3
From Table F.1 of National Fuel Gas
code Handbook, 2002 (3.5 w.c. col-
umn)
Orifice required at Sea Level: # 50
From Table F.4 of National Fuel Gas
code Handbook, 2002
Orifice required at 5000 ft. elevation
(4% de-rate per thousand ft): # 51
Orifice required at 8000 ft. elevation
(4% de-rate per thousand ft): # 52
5000 to
6000 to
7000 to
5999 ft
6999 ft
7999 ft
49
49
50
50
50
50
51
51
51
51
52
52
52
53
53
8000 to
8999 ft
50
51
52
52
53
51