Rheem RGFE Installation Instructions Manual page 119

Dedicated horizontal high efficiency modulating condensing gas furnace
Table of Contents

Advertisement

PROGRAMMING
Energy Saving Factory Pre-Program
The (-)HC-TST401MDMS thermostats are programmed with the energy saving settings shown in the table below for all days
of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button.
The table below shows the factory set heating and cooling schedule for all days of the week.
Heating
6:00 AM
Program
Cooling
6:00 AM
Program
* You can eliminate these two program periods in the configuration menu (reference #3) if the building is occupied all day.
Day will change to 6:00 am and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The (-)HC-TST401MDMS comes configured for 7 day programming and can also be configured for 5+1+1 programming (see
configuration section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your
own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day fill in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
In Heating, lower temperatures will save energy.
In Cooling, higher temperatures will save energy.
If you plan on using Auto Changeover, do not program the heating higher than the cooling.
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Wake Up
Heating
Program
(Morning)
6:00 AM
70 F Auto 8:00 AM
MON
TUE
WED
THU
FRI
6:00 AM
70 F Auto 8:00 AM
SAT
6:00 AM
70 F Auto 8:00 AM
SUN
Cooling
Wake Up
Program
(Morning)
6:00 AM
78 F Auto 8:00 AM
MON
TUE
WED
THU
FRI
6:00 AM
78 F Auto 8:00 AM
SAT
6:00 AM
78 F Auto 8:00 AM
SUN
56
* Wake Up
Leave For Work
(Morning)
(Day)
70 F
8:00 AM
78 F
8:00 AM
Leave For Work
Fan
(Day)
62 F Auto 5:00 PM
62 F Auto 5:00 PM
62 F Auto 5:00 PM
Leave For Work
Fan
(Day)
85 F Auto 5:00 PM
85 F Auto 5:00 PM
85 F Auto 5:00 PM
* Return Home
(Evening)
62 F
5:00 PM
70 F
85 F
5:00 PM
78 F
Return Home
Fan
(Evening)
Fan
70 F Auto 10:00 PM 62 F Auto
70 F Auto 10:00 PM 62 F Auto
70 F Auto 10:00 PM 62 F Auto
Return Home
Fan
(Evening)
Fan
78 F Auto 10:00 PM 82 F Auto
78 F Auto 10:00 PM 82 F Auto
78 F Auto 10:00 PM 82 F Auto
Go To Bed
(Night)
10:00 PM
62 F
10:00 PM
82 F
Go To Bed
(Night)
Fan
Go To Bed
(Night)
Fan
119