E-5
PROBLEMS
(SYMPTOMS)
No auxiliary power
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
FUNCTION PROBLEMS
1. Circuit Breakers open.
2. Faulty connections to auxiliary
receptacles.
3. GFCI Receptacle (if installed) may
have tripped.
CAUSE
1. Check and reset breakers. If
2. Check connections.
3. Follow "GFCI Receptacle Testing
CAUTION
SAE-500™
RECOMMENDED
COURSE OF ACTION
breakers keep tripping check con-
nections to auxiliary receptacles.
Also make sure load does nor
exceed receptacle's current rating.
and Resetting Procedure" in the
MAINTENANCE section of this
manual.