3-3. Video Signal System
3. Select "DUAL MODE" of the rotary encoder.
Press the rotary encoder.
* Others *
Reference
Analog
>Dual Mode
OFF
FRONT PGM
PGM1
PGM INPUT
SERIAL
SDI AUDIO
ON
CF Shift
4. Set OFF (normal mode), Primary or Secondary
according to the relevant CCU.
For the details, refer to Section 2-2, "Setup Menu".
3-12 (E)
Setting using the MSU-700A/750
1. Press the CONFIG button of the MODE block of the
MSU-700A/750 to light up the button.
The configuration menu will be displayed.
Configuration Menu
Camera
CCU
CNU
MSU
2. Press [CCU].
The CCU configuration items will be displayed.
CCU Configuration
CCU
BARS
Mode Set
Char Set
Return
Matrix
3. Select [CCU|Mode|Set] from the configuration
items.
4. The CCU mode setting display appears.
Select OFF (normal mode), Primary or Secondary
according to the relevant CCU.
CCU Mode Setting
Dual Camera Mode
Primary
Secondary
OFF
Exit
Exit
1/2
Bars
Character
ON