Sony CCU-900 Installation And Maintenance Manual page 12

Camera control unit
Hide thumbs Also See for CCU-900:
Table of Contents

Advertisement

1-2. Connectors and Cables
INTERCOM/TALLY/PGM (D-sub 25-pin, Female)
13
25
_ _ _ _ _ EXT VIEW _ _ _ _ _
No.
Signal
1
ENG (R) (X) OUT
2
ENG (R) (Y) OUT
3
ENG (G)
4
ENG (T) (X) IN
5
ENG (T) (Y) IN
6
PGM1 (X) IN
7
PGM1 (Y) IN
8
PGM1 (G) IN
9
GND
10
AUX8
11
R TALLY (X) IN
12
R TALLY (Y) IN
13
GND
14
PROD (R) (X) OUT
15
PROD (R) (Y) OUT
16
PROD (G)
17
PROD (T) (X) IN
18
PROD (T) (Y) IN
19
PGM2 (X) IN
20
PGM2 (Y) IN
21
PGM2 (G) IN
22
AUX7
23
AUX6
24
G TALLY (X) IN
25
G TALLY (Y) IN
1-4 (E)
1
14
(0 dBu = 0.775 Vrms)
Specifications
ENG SYSTEM RECEIVE
0 dBu BALANCED
GND for ENG
ENG SYSTEM TALK
0 dBu BALANCED
_20 dBu/0 dBu
(Selectable with S201/AT board)
GND for AUX
ON : 24 V dc, TTL (H), SHORT
OFF : 0 V dc, TTL (L), OPEN
CHASSIS GND
PROD SYSTEM
RECEIVE 0 dBu BALANCED
GND for PROD
PROD SYSTEM TALK
0 dBu BALANCED
_20 dBu/0 dBu
(Selectable with S202/AT board)
ON : 24 V dc, TTL (H), SHORT
OFF : 0 V dc, TTL (L), OPEN
WF MODE (D-sub 15-pin, Female)
8
15
_ _ _ _ _ EXT VIEW _ _ _ _ _
No.
Signal
1
NC
2
NC
3
RECALL9
4
NC
5
RECALL2
6
RECALL3
7
RECALL1
8
RECALL4
9
GND
10
NC
11
RECALL10
12
RECALL5
13
RECALL6
14
RECALL7
15
RECALL8
1
9
Specifications
No connection
No connection
LOW ACTIVE
No connection
LOW ACTIVE
No connection
LOW ACTIVE
CCU-900/900P IMM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccu-900pBkp-9330

Table of Contents