6. Install the replacement fan in the location from which you removed the failed
7. Connect the replacement fan cable to the system board.
If you have other options to install, do so now. Otherwise, go to "Completing the
installation" on page 18.
Replacing the battery
When replacing the battery, you must replace it with a lithium battery of the same
type from the same manufacturer. To avoid possible danger, read and follow the
safety statement below.
To order replacement batteries, call 1-800-772-2227 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada,
call your IBM reseller or IBM marketing representative.
Note: After you replace the battery, you must reconfigure your system and reset
the system date and time.
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Complete the following steps to replace the battery:
1. Read the safety information beginning on page v and follow any special
2. Turn off the server and peripheral devices, and disconnect the power cord and
3. Remove the riser-card assembly.
4. Remove the battery:
Note: Correct airflow is from the front to the rear of the server.
fan.
handling and installation instructions supplied with the replacement battery.
all external cables. Remove the cover (see "Removing the cover" on page 9).
a. Press the battery release tab to release the battery from the socket.
b. Lift the battery out of the socket.
Chapter 2. Installing options
17