Product Specific & Important Safety Information; Appliance Certification; Btu Specifications; Non-Combustible Materials - Outdoor Lifestyles ODVILLAG-36T Installation Manual

Outdoor decorative gas appliance
Table of Contents

Advertisement

2
Product Specific & Important Safety Information
A. Appliance Certification
MODELS: ODVILLAG-36T, ODVILLAG-36H,
ODVILLAG-42T, ODVILLAG-42H
LABORATORY: Underwriters Laboratories Inc. (UL)
TYPE: Outdoor Decorative Gas Appliance
STANDARD: ANSI Z21.97-2012/ CSA 2.41-2012
This product is listed to ANSI standards for outdoor deco-
rative gas appliances.
Outdoor Lifestyles is a registered trademark of Hearth &
Home Technologies.
When an appliance is for connection to a fixed piping
system, the installation must conform with local codes,
or in the absence of local codes with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or International Fuel
Gas Code.
B. BTU Specifications
This appliance is listed for use with the outdoor decora-
tive gas log set supplied.
Maximum allowable BTU ratings:
Unit
ODVILLAG-36
ODVILLAG-42
C. Non-Combustible Materials
• Materials which will not ignite and burn, composed of
any combination of the following:
- Steel
- Brick
- Concrete
- Glass
• Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
D. Combustible Materials
• Materials made of or surfaced with any of the following
materials:
- Wood
- Plant fibers
- Plywood/OSB
• Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
Outdoor Lifestyles • Villa Gas Owners/Installation Manual • 4072-170 • Rev C • 04/01/14
Max BTU/HR
40,000
42,000
- Iron
- Tile
- Slate
- Plasters
- Compressed paper
- Plastic
- Sheet rock (drywall)
E. High Altitude Installations
NOTICE:
If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certified without a
reduction of input rate for elevations up to 4500 feet
(1370 m) above sea level. Please consult provincial and/
or local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orifice size.