Constructing The Appliance Enclosure - Outdoor Lifestyles ODVILLAG-36T Installation Manual

Outdoor decorative gas appliance
Table of Contents

Advertisement

Upper front can be
covered with
non-combustible
material or removed
and replaced with
non-combustible
material.
36 in.
(914 mm)
Figure 4.3
Framing Dimensions
C. Constructing the Appliance Enclosure
NOTICE:
Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.
WARNING! Risk of Fire!
clearances to appliance.
• Insulation and other materials must be secured to
prevent accidental contact.
• The enclosure must be properly blocked to prevent
blown insulation or other combustibles from entering
and making contact with fireplace or chimney.
• Failure to maintain airspace may cause overheating and
a fire.
Outdoor Lifestyles • Villa Gas Owners/Installation Manual • 4072-170 • Rev C • 04/01/14
B
A
0 in. to level
of standoffs
Maintain specified air space
Framing Dimensions
ODVILLAG-36
ODVILLAG-42
Use only noncombustible
material below the top of
the top standoffs.
C
1/2 in. (13 mm)
84 in.
(2134 mm)
to ceiling
0 in.
Combustible flooring may be installed next
to the front of the appliance.
A
B
in.
21 1/2
39 3/4
42
mm
546
1010
1067
in.
21 1/2
39 3/4
48
mm
546
1010
1219
1/2 in.
(13 mm)
1/2 in. (13 mm)
Combustible
facing
0 in.
C
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Odvillag-36hOdvillag-42tOdvillag-42h

Table of Contents