Duct Grounding

Under some circumstances, static electricity can be
generated in dust collection systems and can collect on
the plastic ducting surfaces. If this static electricity is
discharged through a spark, there is a potential for the
dust and oxygen in the ducting to ignite.
Therefore, your dust collection system must be grounded
one of three ways.
First, the ground is achieved by means of using
metal ducting throughout the system. All static
electricity buildup is carried through the continu-
ous metal ducting and dissipated through the dust
collector impeller housing.
Second, for plastic pipe or hose ducting systems,
install an uncoated bare copper wire inside
the entire length of all ducting. An additional
wire must be spiral-wrapped on the outside of
all the ducting (see Figure 12). Both wires must
be connected to the dust collector impeller hous-
ing (see Figure 13) so all static electricity inside
and out of the ducting is carried through the
wires and dissipated through the dust collector
ground.
If the system has branches, place wires in the
same fashion and connect to the wires on the
main pipe/hose with wire nuts. If blast gates
are to be used, drill exit and entrance holes on
either side of the blast gate to allow wire to be
fed out of and into the system (see Figure 14).
Third, if you use a combination of metal and
plastic ducting, make sure that you use a copper
grounding wire to ground all plastic connections
with the metal ducting so no part of the ducting
is insulated by the plastic.
Note : For more in-depth information on Dust Collection
System design, refer to refer to The Dust Collection
Handbook (ISBN 0-9635821-2-7), which is available for
purchase through any Woodstock/SHOP FOX
Model W1727 (For Machines Mfg. Since 5/09)
Figure 12. Typical dust collector with
ground wire installed inside and around
Figure 13. Typical dust collector impeller
housing with ground wires secured to
Dealer.
®
Figure 14. Ground wires bypassing a blast
-12-
pipe .
the housing.
gate.