Finalizing the Installation
Install the LP pilot orifice following the directions below.
4
(a) Use a 7/16" open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly
then replace the pilot hood, tightening the pilot hood until it is snug (do not over-tighten).
a
5
Replace the firebox components. Install the logs and embers. Replace the glass.
6
Use the included torx wrench to remove the stepper motor (it may be discarded). The stepper motor
(adjustable regulator) has an installation sheet included with it – make sure to follow all of the
directions. Place the stepper motor on the gas control valve (see below) – MAKE SURE IT IS
CORRECTLY ORIENTED. Secure using the screws included with the motor (see below) – tighten to
25 Lb-inches. Leak test this area after installation to verify proper installation.
7
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve.
© Travis Industries
Natural Gas Orifice = .020N (3way)
.018N (2way)
LP (Propane) Orifce = .014LP
7/16" Wrench
4131114
(for qualified installers only)
b
.020N
or
.018N
.014LP
100-01319