40

Installation Example - Build-In with Horizontal Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
See "Vent Termination"
Horizontal Termination*
* Travis Ind. MIn. Vent Kit (SKU 98900168) Includes
a 4'' (102mm) section and horizontal termination.
NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm)
exterior wall, the termination may not fit flush against
the exterior wall. You may wish to place framing
around the termination to fill the gap.
Top View
NOTE:
1/2'' (13mm) Clearance to
sides and back of fireplace.
© Travis Industries
Installation
for full requirements.
4'' (102mm) Section*
(for qualified installers only)
SIDE OF FIREPLACE
Firestop
Insulation
NOTE: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
Drywall
Optional Tile
4131114
Drywall
Optional Tile
100-01319