Service and Repairs

See Chapter 5 - - Electrical System (S/N Below 30101)
for additional Service and Repairs information. Only
changed and new information is provided in this Chap-
ter.

Circuit Protection

On model 30580 (S/N 30101 and up), one 5 Amp fuse
and two 15 Amp fuses are used for circuit protection. In
addition, a 40 Amp circuit breaker with reset button is
used for protection of the entire wiring circuit. The fuses
and circuit breaker are located under the control panel
to the right of the seat (Fig. 13). If total loss of electrical
function occurs, find and correct the malfunction before
pressing the reset button.
On models 30581, 30582 and 30583, one 5 Amp fuse
and two 15 Amp fuses are used for circuit protection.
The fuses are located under the control panel to the right
of the seat. In addition, four (4) fusible links are used in
the wire harness rather than the circuit breaker that was
used on model 30580. The fusible links attach to the
starter motor terminal (Fig. 14). Replacement fusible
links are identified in the Parts Catalog. See wire har-
ness drawings in Chapter 9 -- Foldout Diagrams for addi-
tional information.
IMPORTANT: Do not install fuses in fuse block on
left side of instrument panel. Fuses should be
installed in this fuse block only if machine is
equipped with a road light kit.
Fuses can be removed to check continuity. The test me-
ter should read less than 1 ohm.
Electrical System (S/N 30101 & Up) (Rev. E)
Page 8 - - 14
Rev. G
2
1
Figure 13
1. Circuit breaker reset button
2. Fuse block
1
2
Figure 14
1. Engine starter motor
2. Fusible links
Figure 15
Groundsmaster 580--D