Microprocessor problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3550 M3 Types 4254 and 7944," on page 159 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Symptom
The server goes directly to the
POST Event Viewer when it is
turned on.
92
IBM System x3550 M3 Types 4254 and 7944: Problem Determination and Service Guide
Action
1. Correct any errors that are indicated by the light path diagnostics LEDs (see
"Light path diagnostics" on page 101).
2. Make sure that the server supports all the microprocessors and that the
microprocessors match in speed and cache size. To view the microprocessor
information, run the Setup utility and select System Information → System
Summary → Processor Details.
3. (Trained service technician only) Make sure that microprocessor 1 is seated
correctly.
4. (Trained service technician only) Remove microprocessor 2 and restart the
server.
5. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board