PL
DESCRIPTION AND OPERATION
HELPFUL INFORMATION . . . . . . . . . . . . . . . . . . 3
DESCRIPTION AND OPERATION
POWER MIRRORS
Power for the power mirror switch is supplied on
circuit F121. This circuit is protected by a 15 amp
circuit breaker located in the right front door. Power
for the circuit breaker is supplied by circuit F21.
The F21 circuit is protected by a 30 amp circuit
breaker. This circuit breaker also supplies power to
the power windows.
The power mirror switch has a right and left posi-
tion. Moving the switch to either of these positions
changes the voltage path internal to the switch (ie.
changes polarity at the motors).
When the switch is moved to the RIGHT position
and mirror movement UP is selected, voltage is sup-
plied to the mirror on circuit P92 and the ground
path is supplied on circuit P90. The P90 circuit con-
nects from the mirror to the normally CLOSED con-
tacts in the mirror relay located in the right door.
When the right mirror DOWN movement is
selected voltage is supplied through the switch to cir-
cuit P110. The P110 circuit connects from the switch
to the power mirror relay located in the door, coil
side. Power on the coil side causes the contacts in the
relay to CLOSE connecting circuits F121 and P90.
The P90 circuit then supplies power to the DOWN
side of the motor. Ground for the motor is supplied
on circuit P92 back to the switch and then connects
to circuit Z8. The Z8 circuit connects from the switch
to its grounding point on the right instrument panel
center support.
If right door mirror movement LEFT is selected
voltage is supplied through the P94 circuit and the
8W - 62 POWER MIRRORS
8W-62 POWER MIRRORS
INDEX
page
ground is passed through circuit P91. When left mir-
ror RIGHT movement is selected the power and
ground are reversed.
and mirror movement UP is selected, voltage is sup-
plied to the mirror on circuit P93 and the ground
path is supplied on circuit P90. The P90 circuit con-
nects from the mirror to the normally CLOSED con-
tacts in the mirror relay located in the right door.
voltage is supplied through the switch to circuit
P110. The P110 circuit connects from the switch to
the power mirror relay located in the door, coil side.
Power on the coil side causes the contacts in the
relay to CLOSE connecting circuits F121 and P90.
The P90 circuit then supplies power to the DOWN
side of the motor. Ground for the motor is supplied
on circuit P93 back to the switch and then connects
to circuit Z8. The Z8 circuit connects from the switch
to its grounding point on the right instrument panel
center support.
age is supplied through the P95 circuit and the
ground is passed through circuit P91. When left mir-
ror RIGHT movement is selected the power and
ground are reversed.
HELPFUL INFORMATION
the fuse block
right door
panel right center support
POWER MIRRORS . . . . . . . . . . . . . . . . . . . . . . . 3
When the switch is moved to the LEFT position
When the left mirror DOWN movement is selected
If left door mirror movement LEFT is selected volt-
• Check the 30 amp circuit breaker located behind
• Check the 15 amp circuit breaker located in the
• Check the grounding point at the instrument
8W - 62 - 3