EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
A1
B1
Top Cover
A
1. Remove the two screws.
A) Silver / M3x6 / S-Tite: Two pieces
2. Disengage the two hooks by inserting a flat-blade screwdriver or similar tool into a gap
between the Top Cover and the Paper Feed Unit, and remove the Top Cover.
DISASSEMBLY AND ASSEMBLY
Top Cover
A
Hooks
Main Unit Disassembly/Reassembly
A2
Grounding Terminal
A
Connector
1. Remove the two screws.
A) Silver / M3x6 / S-Tite: Two pieces
2. Disconnect the five connectors, and remove the PF Main Board.
The grounding terminal should be screwed together with the PF Main Board.