Supplementing The Heat Pump With A Groundwater System - Bosch EHP 6-11 LW User And Installation Manual

Heat pump compress 3000
Table of Contents

Advertisement

Preparations before connection
Supplementing the heat pump with a
groundwater system
If the heat pump is installed for groundwater instead of rock, soil or lake, it
must be supplemented with an intermediate heat exchanger. The interme-
diate heat exchanger protects the heat pump from contamination, clogging
and freezing.
A groundwater pump with non-return valve is installed at the bottom of
the bore hole. The pump is used to pump the groundwater from the water
source to the intermediate heat exchanger. Heat is transferred to the
heat transfer fl uid in the intermediate heat exchanger. The water is then
pumped to a recharge well. The intermediate exchanger is installed in the
boiler room or the like.
A fi lter has to be used in the water circuit. A similar fi lter type as in the
brine circuit is recommended. A large fi lter is preferable if there is a risk
for much contamination.
The circuit to the heat pump is installed in the same way as described
earlier i.e. with fi lling unit, expansion tank and safety valve. The circuit
should also be protected against freezing down to -15ºC.
Groundwater
Recharge well
Filling unit
Exp.
Intermediate
Filter
heat exchanger
Safety valve
50
Note
The intermediate heat exchange
should be connected against the fl ow.
In addition, the pipe from the ground-
water well is connected to the bottom
of the intermediate heat exchanger so
that the fl ow goes upwards.
To the heating system