IBM NeXtScale System Planning And Implementation Manual page 226

Table of Contents

Advertisement

Description
NetFn
Show
0x32
information
about node size
Show Node
0x32
Power
Consumption in
watts
208
IBM NeXtScale System Planning and Implementation Guide
CMD
Data
0x99
Request Data:
Byte 1: Node number: 0x1 to 0x0c for Node 1 to 12
Response Data:
Byte 1: Completion code (0x00) or out of range (0xC9)
Byte 2: Node Physical Width
Byte 3: Node Physical Height
Byte 4: Add-on Valid
Byte 5: Add-on Width
Byte 6: Add-on Height
0x98
Request Data:
Byte 1 options:
Node number: 0x1 to 0x0c for Node 1 to 12
Chassis: 0x0d
Response Data:
Byte 1: Completion code (0x00)
Byte 2: Power minimum (LSB)
Byte 3: Power minimum (MSB)
Byte 4: Power average (LSB)
Byte 5: Power average (MSB)
Byte 6: Power maximum (LSB)
Byte 7: Power maximum (MSB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n1200Nextscale nx360 m4

Table of Contents