Outline dimension drawings
FR-A720-30K, 37K, 45K, 55K
FR-A740-30K, 37K, 45K, 55K
FR-A720-30K
FR-A740-30K
FR-A720-37K, 45K
FR-A740-37K, 45K, 55K
FR-A720-55K
FR-A740-75K, 90K
2-φ12hole
400
465
178
2-φd hole
W2
W1
W
Inverter Model
W
325
435
465
W1
W2
H
H1
270
10
550
530
380
12
550
525
410
12
700
675
DC reactor supplied
Rating plate
P1
W 2
DC Reactor
Model
FR-HEL-H75K
3.2
300
(FR-A740-75K)
FR-HEL-H90K
(FR-A740-90K)
3.2
D
H2
d
D
10
10
195
15
12
250
15
12
250
2-terminal
(for M12 bolt)
P
P1, P
E
W1
4-installation hole
(for M6 screw)
Earth (ground) terminal
(for M6 screw)
W
H
H1
W1
140 120 320 295 185
150 130 340 310 190
Unit: mm
(
)
Within D
Mass
D
(Kg)
16
20
(
Unit: mm
)