COMPULSORY VALVE OPERATION CHECK MODE
Engine (DIAGNOSTICS)
14. Compulsory Valve
Operation Check Mode
A: OPERATION
1) Prepare Subaru Select Monitor kit. <Ref. to
EN(H6)-8
PREPARATION
Description.>
2) Connect diagnosis cable to Subaru Select
Monitor.
3) Insert cartridge into Subaru Select Monitor.
<Ref. to EN(H6)-8 PREPARATION TOOL, General
Description.>
4) Connect test mode connector at the lower por-
tion of instrument panel (on the driver's side), to
the side of the center console box.
S048528
S048528A16
TOOL,
General
S2M0285
S2M0286A
B2M3716A
5) Connect Subaru Select Monitor to data link
connector.
(1) Connect Subaru Select Monitor to data link
connector located in the lower portion of the
instrument panel (on the driver's side).
(2) Connect diagnosis cable to data link con-
nector.
CAUTION:
Do not connect scan tools except for Subaru
Select Monitor and OBD-II general scan tool.
6) Turn ignition switch to ON (engine OFF) and
Subaru Select Monitor switch to ON.
7) On the
the {2. Each System Check} and press the [YES]
key.
8) On the
screen, select the {Engine Control System} and
press the [YES] key.
9) Press the [YES] key after displayed the infor-
mation of engine type.
10) On the
select the {System Operation Check Mode} and
press the [YES] key.
11) On the
display screen, select the {Actuator ON/OFF
Operation} and press the [YES] key.
12) Select the desired compulsory actuator on the
Actuator ON/OFF Operation
and press the [YES] key.
13) Pressing the [NO] key completes the compul-
sory operation check mode. The display will then
return to the
screen.
EN(H6)-52
Main Menu
display screen, select
System Selection Menu
Engine Diagnosis
display screen,
System Operation Check Mode
display screen
Actuator ON/OFF Operation
B2M2960B
S2M0288A
display