3.37 [1-1] Slot—Card Property - T1 type
Flash—Flash Width (TIE)
Specifies the maximum length of a flash signal received from a TIE line that the PBX can recognise as a
hookswitch flash signal.
Value Range
8 ´ n (n=3–191) ms
Maintenance Console Location
3.37 [1-1] Slot—Card Property - T1 type
Programming Manual References
None
Feature Guide References
None
Caller ID—Caller ID Start Code
Selects the DTMF code used to detect the beginning of a Caller ID series.
Value Range
*, #, A–D
Maintenance Console Location
3.37 [1-1] Slot—Card Property - T1 type
Programming Manual References
None
Feature Guide References
1.18.1 Caller ID
Caller ID—Caller ID Information End Code
Selects the delimiter used to separate multiple parameters in a Caller ID series.
Value Range
*, #, A–D
Maintenance Console Location
3.37 [1-1] Slot—Card Property - T1 type
342