4 ADVANCED SETTINGS

4.1 Service Menu

SYSTEM DATA

NMEA DATA
NMEA PORT TEST
Master reset?
No
Yes
SYSTEM DATA
Steer compass
220.0°M
Monitor comp.
225.2°
Rudder
P 03.07
Steer Course
240°
System Filter Values
WAVES
Fc: 05s Db:04°
Input voltage
11V
Drive out
100%
Clutch/bypass
installed
FU50 SW 1.3.00
20222410 / B
Select STANDBY mode and then enter the Installation Menu by
pressing and holding the NAV/SETUP button for 5 seconds.
Select "SERVICE" by pressing the
confirm by rotating the course knob clockwise.
"SYSTEM DATA" and "NMEA DATA" are test functions to
analyze data processed by the AP50.
To exit the menu, press any mode key (STBY, AUTO or NAV).
System Data
Select "SYSTEM DATA" by rotating the course knob
clockwise. This menu provides you with additional system data
that can be useful when testing or trouble shooting the system.
Steer compass
Steering Compass readout, M=Magnetic, T = True.
Monitor comp.
Monitor Compass readout.
Rudder
Rudder angle. Normally between 0 and 45°.
Steer Course
Current steered course in AUTO and NAV modes.
System Filter Values
Values set by the automatic sea state filter (in AUTO and NAV
modes).
Fc = Wave filter time constant in seconds.
Db = Deadband in degrees to each side of the set course. The
boat has to be outside the deadband before the autopilot
responds.
Input voltage
Mains voltage on input terminals.
Drive out
Power needed to drive the unit (in percent of full [100%]) to get
satisfactory rudder speed. (Refer to page 85 for adjustment).
Advanced Settings
(STBD) button and
79

Advertisement

Table of Contents
loading

Table of Contents