Installation
DINING
KITCHEN
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Smoke Alarms for Additional Protection
Ionization Type Smoke Alarm with
Hush® Control or Photoelectric Type
SINGLE FLOOR PLAN
IMAGE 1A
• Install smoke alarms on sloped, peaked or cathedral
ceilings at or within 0.9 m (3') of the highest point
(measured horizontally). NFPA Standard 72 states:
"Smoke alarms in rooms with ceiling slopes greater than
0.3 m in 2.4 m (1 foot in 8 feet) horizontally shall be
located on the high side of the room." NFPA Standard
72 states: "A row of detectors shall be spaced and
located within 0.9 m (3') of the peak of the ceiling
measured horizontally" (Image 2B).