Kenwood KDC-M7024 Service Manual page 6

Cd receiver
Hide thumbs Also See for KDC-M7024:
Table of Contents

Advertisement

KDC-M7024/MP822
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
23
BU_DET
24
ACC_DET
25
SW5V
EXT_AMP_CONT
26
NC
27
DIMMER
28
ANT_CON
29
P_ON
30
ILL_ON
31
RESET
32
XT1
33
XT2
34
REGC
35
X2
36
X1
37
VSS
38
VDD
39
CLKOUT
40
LX_REQ_M
41
LX_MUTE
42
LX_CON
43
LX_RST
44
CD_MECHA+B I/O
45
TYPE0
46
TYPE1
47
IC2_TYPE0
48
IC2_TYPE1
49
NC
50
E2P5V
51
DSI
52
L_CE
53
L_INH
54
VOL A
55
BVDD
56
BVSS
57
VOL B
58
M_RST
59
M_STOP
60
CD_SW3
61
LO/EJ
62
MOSW
6
I/O
Module
Purpose / Description
I
Extra
Momentary power dropped detection.
I
Extra
ACC detection.
I/O
Power supply
5V power supply.
O
Extra
External amplifier control.
O
NC (Without EXT_AMP_CONT model)
I
Extra
Small lamp detection.
O
Extra
Antenna control.
SW 14V, SW 5V control, AD reference
I/O
Power supply
voltage control output.
I/O
Power supply
FL, illumination output.
-
-
Sub clock.
-
Sub clock.
-
-
Main clock.
-
Main clock.
-
-
-
O
LX
Communication request to external slave.
I
LX
Mute request from external slave.
O
LX
External slave select.
Reset output to external slave µ-com.
O
LX
Power supply
DC 5.0V output.
I
Extra
Destination select.
I
Extra
Destination select.
I
Extra
IC2 destination.
I
Extra
IC2 destination.
O
NC
I/O
Power supply
E2PROM, DA converter power supply control.
I/O
To panel
DSI control.
O
To panel
Chip enable output to LCD driver.
O
To panel
Inhibit signal output to LCD driver.
I
To panel
VOL input.
-
-
I
To panel
VOL input.
O
CD
Reset output to CD mechanism.
O
CD
Stop request to CD mechanism.
I
CD
DC down switch detection.
I/O
CD
CD mechanism loading/eject switch.
O
CD
CD mechanism motor driver switch.
Truth table
Processing Operation
Backup : L,
No backup, momentary power dropped : H
With ACC : L, Without ACC : H
ON : L, OFF : Hi-Z
Refer to external amplifier control.
Output : L
ON : L, OFF : H
Tuner ON : H, Other source With RDS last FM
w
: H, Other source with RDBS TI ON last FM : H
Power ON : H, Power OFF : Hi-Z
ON : H, OFF : Hi-Z
32.768kHz
32.768kHz
Connect to 1µF capacitor.
20MHz
20MHz
Request : L
Mute ON : H
ON : H, OFF : L
Normally : L, After system reset : H (400ms
or more) and then L
CD source : H, Except CD source : L,
ON : Fast 50ms than M_STOP,
OFF : Slow 50ms than M_STOP
w
w
w
w
Output : L
ON : L, OFF : Hi-Z
ON : L, OFF : Hi-Z
Normally : H, Reset, momentary power dropped : L
Normally : H, Reset : L (Per mechanism control)
Stop : L, CD : H
Chucking : H
Stop, brake : Hi-Z, Loading : L, Eject : H
Loading, eject, brake : H

Hide quick links: