Microcomputer's Terminal Description - Kenwood KDC-M7024 Service Manual

Cd receiver
Hide thumbs Also See for KDC-M7024:
Table of Contents

Advertisement

Ref. No.
Application/Function
Q53
Noise buffer
Q54
E-vol mute SW
Q55~60
Pre-out mute SW
Q63
E2P 5V SW
Q102, 103
AM+B SW
Q104
Composite signal buffer for RDS

MICROCOMPUTER'S TERMINAL DESCRIPTION

SYSTEM MICROCOMPUTER : UPD703030GC014 (X25-966 : IC1)
Pin No.
Pin Name
I/O
1
PLL_DATA
I/O
2
AM+B
I/O
3
(FM+B)
O
4
V_ILL PAN_E2P DATA I/O
5
V_ILL PAN_E2P CLK I/O
6
EVDD
-
7
EVSS
-
8
AFS
O
9
BEEP
O
10
REMO
I
11
P_MUTE
O
12
(SVR)
O
13
IC2_SDA
I/O
14
IC2_CLK
I/O
15
P_STBY
O
16
P_CON
I/O
17
DIMMER_CONT
O
18
TEST
-
19
NC
O
20
MUTE
O
21
PRE_MUTEL
O
22
PRE_MUTER
O
COMPONENTS DESCRIPTION
When a base gose Hi, mute SW is turned on.
When a base gose Hi, Pre-out is muted.
When Q63'base gose Lo, E2P 5V is out.
When Q102'base gose Hi, AM+B is out.
Module
Purpose / Description
Tuner
Data output/input with F/E.
Power supply
AM+B.
Power supply
FM+B (S01 F/E only).
To panel
V-ILL D/A converter (V-ILL, LCD), E2PROM data.
To panel
V-ILL D/A converter (V-ILL, LCD), E2PROM clock.
Tuner
Noise detection time constant switching.
Audio
Beep output.
Extra
Remote control input (Panel, External display).
Audio
Power IC MUTE output.
Audio
Power IC SVR discharge circuit control.
CD
CD mechanism data line.
Audio
IC2 data line.
Extra
ROM correction data line.
CD
CD mechanism clock line.
Audio
IC2 clock line.
Extra
ROM correction clock line.
Audio
Power IC STBY output.
Extra
Power control.
To panel
Dimmer control (W-LED only).
Extra
NC (MP3 mechanism model).
Audio
Mute output.
Audio
PREOUT (L ch) mute.
Audio
PREOUT (R ch) mute.
KDC-M7024/MP822
Operation/Condition/Compatibility
Truth table
Processing Operation
AM operation : H
FM operation : H,
Last FM : H (With RDS, RBDS model)
FM seek, AF search : L, Receiving : H, Auto 0 : L
Power OFF : L, All OFF : L, TEL mute : L
Power OFF momentary power dropped
: H (5 second) and then L
Power IC ON : H, Power IC OFF : L, All OFF : H
Power ON : H, Power OFF : Hi-Z, All OFF : Hi-Z
Dimmer : Pulse control,
Frequency : 1kHz, Normally : H
Connect to GND.
w
Output : L
ON : OPEN, OFF : L
M MUTE L is L : L (CD), Momentary power
dropped : L, 2 zone, NAVI interrupt : Fixed H
M MUTE R is L : L (CD), Momentary power
dropped : L, 2 zone, NAVI interrupt : Fixed H
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-mp822

Table of Contents