Pre-Installation Information; Before You Start; Fireplace Location - Vermont Castings CDVR33n Installation And Operating Instructions Manual

Cdvsc7 series; cdv7 series direct vent gas fireplace
Table of Contents

Advertisement

pRe-InSTallaTIon InFoRMaTIon

BeFoRe you STaRT

Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
Fireplace (Firebox and Burner System)
Log Set
Rock Wool
ITeMS RequIReD FoR InSTallaTIon
Tools:
Phillips Screwdriver
Hammer
Saw and/or saber saw
Electric Drill and Bits
Pliers
Square
Caulking Material (Noncombustible)
Fireplace Surround Material (Noncombustible)
Piping Complying with Local Codes
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
Do not fill spaces around firebox with
insulation or other materials. This could
cause a fire.
FIReBox FRaMInG FoR CDVR
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following Figure
2 for your specific installation requirements. Refer to Figure
2 for firebox dimensions. The framing headers may rest on
the top of the firebox standoffs. Do not bring headers
below top of standoffs. noTe: CDVR33SC7 &
CDVR33117 do not have standoffs.
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When the
firebox is installed directly on carpeting, tile, or other com-
bustible material, other than wood flooring, the firebox shall
be installed on a metal or wood panel extending the full
width and depth of the enclosure.
FIReBox FRaMInG FoR CDVT
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following Figure
3 for your specific installation requirements. Refer to Figure
3 for firebox dimensions. The framing headers may rest on
the top of the firebox standoffs. Do not bring headers
below top of standoffs.
69D3011
Volcanic Rock
Building Supplies:
Framing Materials
Wall Finishing Materials
Level
Tee Joint
Measuring Tape
Pipe Wrench
CDVSC7 & CDV7 Series Gas Fireplace
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When the
firebox is installed directly on carpeting, tile, or other com-
bustible material, other than wood flooring, the firebox shall
be installed on a metal or wood panel extending the full
width and depth of the enclosure.

FIReplaCe loCaTIon

Plan for the installation of your appliance. This includes
determining where the unit is to be installed, the vent con-
figuration to be used, framing and finishing details, and
whether any optional accessories (i.e. blower, wall switch,
or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, includ-
ing permits and inspections.
The following factors should be taken into consideration:
Clearance to side-wall, ceiling, woodwork, and windows.
Minimum clearances to combustibles must be main-
tained.
This fireplace may be installed along a wall, across a
corner, or use an exterior chase. Refer to Figure 4 for
suggested locations.
Location should be out of high traffic areas and away
from furniture and draperies due to heat from appli-
ance.
Never obstruct the front opening of the fireplace.
Do not install in the vicinity where gasoline or other
flammable liquids may be stored.
Vent pipe routing. See Venting section found in this
manual for allowable venting configurations.
These units can be installed in a bedroom. See National
Fuel Gas Code ANSI Z33.1/NFPA 54 — (current
edition), the Uniform Mechanical Code — (current edi-
tion), and Local Building Codes for specific installation
requirements.
E
A
Y
C
D
Y
F
Figure 4 -
Locating Gas Fireplace
** Island (C) and room divider (D) installation is possible as long
as the horizontal portion of vent system (X) does not exceed
0'.
*
When you install your fireplace in (D) room divider or (E) flat on
wall corner positions (Y), a minimum of 4" clearance must be
maintained from perpendicular wall and front of fireplace.
A Flat on
Wall
B Cross
Corner
B
C Island**
D Room
X
Divider*
E Flat on
Wall
Corner*
B
F Chase
Installation
Y 4"
Minimum
LU584-1
Locating unit
2/4/99 djt
9