Restoration Of Scanner Unit Operation Time (Txrx Time) - JRC JMA-9172-SA Instruction Manual

Marine radar equipment
Table of Contents

Advertisement

JMA-9172-SA Instruction Manual
7.4.4

Restoration of Scanner Unit Operation Time (TXRX Time)

The system adds up the following operation time and contains it in the scanner
unit:
• Transmission time
• Motor run time
Clear the above total time when scanner unit motor is replaced.
7.4.4.1
Clear of Motor Run Time (Clear TX Time)
Clear the scanner's motor run time.
Perform the following procedure to clear the motor run time when the scanner motor is
replaced.
Procedures
1)
Open the Serviceman Menu.
2)
Perform the following menu open procedure to open the Clear
Motor Time menu.
3)
Select
The motor run time in the TXRX's internal control circuit is cleared to 0.
7.4.4.2
Save of Antenna Time (Clear Motor Time)
Save the following scanner unit time data from the scanner unit into the display unit.
Perform the following procedure to inherit the scanner unit time data when the TXRX's
internal control circuit is replaced.
Procedures
1)
Open the Serviceman Menu.
2)
Perform the following menu open procedure to open the Clear
Motor Time menu.
Select
3)
The motor run time in the TXRX's internal control circuit is cleared to 0.
>
7.SETTINGS FOR SYSTEM OPERATION
3. Maintenance Menu
5. TXRX Time
1. Clear TX Time
in the Confirmation Menu.
1. Yes
3. Maintenance Menu
5. TXRX Time
2. Clear Motor Time
in the Confirmation Menu.
1. Yes
7- 41
>
7.4 MAINTENANCE MENU
7

Advertisement

Table of Contents
loading

Table of Contents