Sony DCR-TRV240 Service Manual page 111

Digital video camera recorder
Hide thumbs Also See for DCR-TRV240:
Table of Contents

Advertisement

DCR-TRV240/TRV340
1-2-2.
INITIALIZATION OF A, D PAGE DATA
(DCR-TRV340)
Note: The data of page: 0, address: 10 must be "00".
1. Initializing the A, D Page Data
Note1: If "Initializing the A, D Page Data" is performed, all data
of the A page and D page will be initialized. (It is
impossible to initialize a single page.)
Note2: If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
Note3: The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
0
10
3
7
03
4
7
00
5
7
01
6
7
02
7
2
00
8
2
01
9
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
D
10 to 67
A
10 to FF
Procedure
01
Set the data
00
Set the data
00
Set the data
28
Set the data
28
Set the data, and press the PAUSE
button.
Check that the data changes to
"01"
29
Set the data
29
Set the data, and press the PAUSE
button.
Perform "Modification of A, D
Page Data".
Processing after Completing Modification of A, D Page data
Order Page Address Data
1
0
10
2
2
00
3
2
01
Note: If the following symptoms occur after completing of the
"Modification of A, D page data", check that the data of the "Fixed
data-2" addresses of D page are same as those of the same model of
the same destination.
1) The self-diagnosis code "E: 20:00" is displayed on the LCD
screen.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1: The data of page: 0, address: 10 must be "00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, D
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of A, D
Page Data".)
Address
Initial value
00 to 0F
10
00
11 to 15
16
17 to 21
22
23
24
25
26
27 to 29
2A
2B
2C to 36
37
38 to 39
3A
3B to 49
4A
4B
4C
4D
4E
4F to 67
4. A Page Table
Note1: The data of page: 0, address: 10 must be "00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, D
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of A, D
Page Data".)
Address
00 to 0F
10 to 17
Fixed data-1
18
Fixed data-2
19 to FF
Fixed data-1
5-10
Procedure
00
Set the data.
29
Set the data.
29
Set the data, and press PAUSE
button.
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Table. 5-1-3.
Remark
Table. 5-1-4.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv340

Table of Contents