1-2-1.
INITIALIZATION OF D PAGE DATA
(DCR-TRV240)
Note: The data of page: 0, address: 10 must be "00".
1. Initializing the D Page Data
Note1: If the D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of D page data
Note2: The power supply voltage must be 6.1 ± 0.1Vdc.
Adjusting page
D
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
1
0
01
01
2
0
10
00
3
2
00
2D
4
2
01
2D
5
2
02
6
2
00
29
7
2
01
29
8
2. Modification of D Page Data
If the D page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of D Page data
Order Page Address Data
1
2
00
29
2
2
01
29
Note: If the following symptoms occur after completing of the
"Modification of D page data", check that the data of the "Fixed
data-2" addresses of D page are same as those of the same model of
the same destination.
1) The self-diagnosis code "E:20:00" is displayed on the LCD screen.
2) The power is shut off so that unit cannot operate.
Procedure
Set the data
Set the data
Set the data
Set the data, and press the PAUSE
button.
Check that the data changes to
"01"
Set the data
Set the data, and press the PAUSE
button.
Perform "Modification of D Page
Data".
Procedure
Set the data
Set the data, and press the PAUSE
button.
3. D Page Table
Note1: The data of page: 0, address: 10 must be "00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the D Page
Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of D Page
Data".)
Address
Initial value
00 to 0F
10
00
11
12
13 to 32
33
34 to 42
43
44
45
46
47
48
49
4A to 4C
4D
4E to 4F
50
51
52
53
54
55 to 57
58
59
5A
5B
5C
5D to 64
65
66
67
68
69 to 6B
6C
6D
6E
6F
70 to 77
78
79
7A
7B
7C
7D to 8D
8E
8F
90 to B6
B7
B8 to CF
D0
00
D1
00
D2 to FF
5-9
DCR-TRV240/TRV340
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Drum rotation counted time.
(Refer to "4-3. SERVICE MODE".)
Fixed data-1
Table. 5-1-2.