User Programming Mode - Pentair Fleck 5600SXT Downflow Service Manual

Hide thumbs Also See for Fleck 5600SXT Downflow:
Table of Contents

Advertisement

USER PROGRAMMING MODE

User Programming Mode Options
Abbreviation
Parameter
DO
Day Override
RT
Regeneration
Time
H
Feed Water
Hardness
RC or SF
Reserve Capacity
CD
Current Day
NOTE: Some items may not be shown depending on timer
configuration. The timer will discard any changes
and exit User Mode if any button is not pressed for
sixty seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by "DO" in the upper left hand corner of
the screen.
3. Press the Extra Cycle button. Use this display to adjust the
Regeneration Time. This option setting is identified by "RT"
in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust the
Feed Water Hardness. This option setting is identified by
"H" in the upper left hand corner of the screen.
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identified by
"RC" or "SF" in the upper left-hand Corner of the screen.
Description
The timer's day override setting
The time of day that the system
will regenerate (meter delayed,
timeclock, and day-of-week
systems)
The hardness of the inlet water
- used to calculate system
capacity for metered systems
The fixed reserve capacity
The current day of week
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identified by
"CD" in the upper left hand corner of the screen.
7. Press the Extra Cycle button to end User Programming
Mode.
Fleck 5600SXT Downflow JE11 • 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents