AUXILIARY OUTPUT 1 - 2 SPECIAL TIMING
Location 46 contains special timing feature activation for the four auxiliary outputs. Segment 1 corresponds to output 1; Segment 2
corresponds to output 2.
Segments 1 - 2:
1 = On if output should be timed in minutes; Off if timed in seconds.
2 = On if output should latch; Off if output should be timed.
3 = On if output should stop timing upon code entry; Off if the output should continue to time upon code entry.
4 = On if output should only activate between the closing and opening time in loc. 52 and 53.
5 = On if output should only activate between the opening and closing time in loc. 52 and 53.
6 = On if output should be inverted (0 volts going to 12 volts when activated).
7 = Reserved.
8 = Reserved.
47
AUXILIARY OUTPUT 1, EVENT & TIME
Segment 1:
Use Table XIII-1 to select the event that will activate Auxiliary Output 1.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 1, Location 46).
Programming a "0" makes the output follow the event.
48
AUXILIARY OUTPUT 2, EVENT & TIME
Segment 1:
Use Table XIII-1 to select the event that will activate Auxiliary Output 2.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 2, Location 46).
Programming a "0" makes the output follow the event.
49 - 50
RESERVED
Table XIII-1 AUXILIARY OUTPUT EVENT SELECTION
DATA
EVENT
0 /
Burglary Alarm
1  /
Fire Alarm
2  /
24 Hour Alarm
3  /
Trouble Alarm
4  /
Tamper Alarm
5
Yelping Siren (Burglary)
6
Temporal Siren (Fire)
7
Any Siren
8
Any Bypass
9
AC Fail
10
Low Battery
11  /
Duress
12  /
Aux 1 Keypad Zone
13  /
Aux 2 Keypad Zone
14  /
Panic Keypad Zone
15
Keypad Tamper
16  /
Autotest
17
Alarm Memory
18
Entry
˜
Events 49 & 50 require one or more of the following to operate: NX-408E, NX-416E, NX-448E wireless receivers, or NX-1700E card reader
/
If set to follow condition, these events will be 1 second.
Note:
When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s) a particular code will activate.
When LED 8 is on for an authorization, then LEDs 1- 2 correspond to that code activating outputs 1 - 2 respectively. (See programming the
LED keypads on page 7.)
L
51
AUTOTEST CONTROL
Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a A2" to suppress the daily test or a A3" to
Segment 1:
suppress the hourly test if any report has been sent.
Segment 2:
Program the Autotest interval from 1-255 hours/days.
Segment 3:
Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is ignored).
Segment 4:
Program the Autotest report time, number of minutes after the hour.
20
SLOW COMMUNICATOR FORMAT CODES
DATA
EVENT
19
Exit
20
Entry or Exit
21
Armed State
22
Disarmed State
23
Ready
24
Not Ready
25
Fire
26
Fire Trouble
27
Chime
28  /
Expander Trouble
29
Dynamic Battery Test Time
30
Open Period
31
Closed Period
32
Listen-In
33
Line Seizure
34
Ground Start
35
Fail To Communicate
36
Telephone Line Fault
37
Program Mode
WWW.DIYALARMFORUM.COM
2 ............ feature select
2 ............ numerical
2 ............ numerical
DATA
38
Download In Process
39
Smoke Power
40
Short Circuit (Over-current)
41
Box Tamper
42
Siren Tamper
43
Any Open
44
Any Short
45
Any Fault (Open/ Short on Non-Fire Zone)
46  /
Any Alarm
47
Beeping Keypad
48  /
Code Entry (See note below)
49 ˜ / Key FOB Function 1
50 ˜ / Key FOB Function 2
51
Always ON
52
Alarm Flash
53
Armed Away
54
Armed Stay
55
Aux Comm Fail
56
(CP-01) Progress Annunciation
4 ............ numerical