Head.shower; Gray.water.system.option; Heads; Enclosed.heads - Four winns 310 Horizon Owner's Manual

Table of Contents

Advertisement

C. Head Shower
A.head.shower.is.standard..The.shower.unit.is.actu-
ally.a.combination.faucet.and.shower..See.Figure.J6..
The.switch.to.operate.the.water.pump.is.located.at.
the.refreshment.center.or.in.the.head.and.is.marked.
"FRESH WATER".
To.operate.the.head.shower.place.the."FRESH.
WATER" switch "ON". Pull the faucet/shower out from
its.holder.(located.at.the.sink).and.push.the.spray.
nozzle.lever.to.purge.any.air.that.may.be.in.the.sys-
tem. When a steady flow of water is coming from the
shower.nozzle.the.air.has.been.purged..Release.the.
spray nozzle when finished. As the pressure builds,
the.pump.will.automatically.shut.off.at.35.psi.
NOTICE
After showering thoroughly dry areas that may
have gotten wet to prevent possible damage to
any finishes due too excessive wetness.
A.shower.sump.pump.is.incorporated.into.the.drain.
system.of.the.shower..The.shower.drains.into.the.
sump.pump.located.in.the.forward.bilge.compart-
ment,.starboard.of.the.fuel.tank..The.water.will.then.be.
pumped.overboard..If.an.optional.gray.water.system.is.
installed,.the.water.will.be.pumped.into.the.gray.water.
holding.tank.
The.sump.pump.includes.an.automatic.switch.and.is.
protected by a circuit breaker ("SHOWER SUMP") at
the.battery.switch.panel..The.sump.pump.will.automati-
cally.start.as.soon.as.the.water.in.the.sump.reaches.a.
level that will cause the float on the switch to rise.
After showering, let the water flow for a period of time
to flush the pump of soap residue. Check the sump
for.excess.residue..As.necessary.clean.and.rinse.the.
sump..After.rinsing,.the.pump.will.automatically.shut.
off.
If water flow from the shower head appears to be
restricted,.it.may.be.due.to.sediment.accumulating.at.
the.shower.head..If.necessary,.remove.the.shower.
head and clean the discharge holes with a fine wire.
Periodically.check.the.sump.pump.screen.for.clogs.
to.prevent.drainage.problems.from.occurring.in.the.
shower.drain..Refer.to.the.manufacturer's.literature.
included.in.the.owner's.packet.
Sport Boat Waste & Water System - Section J
J - 4
GRAY WATER SYSTEM OPTION
The.gray.water.system.is.optional..The.water.from.
the.galley.sink,.head.sink.and.shower.will.drain.into.
a.sump.and.is.pumped.into.a.gray.water.holding.tank.
respectively. A pumpout fitting labeled WASTE but
designated.for.gray.water.is.provided.on.the.deck..
See.Figure.J4..Refer.to.the.drawings.at.the.end.of.this.
section..
Waste
Gray Water
Fitting
Figure J4: Waste Fittings
NOTICE
Certain geographical areas have restrictions
on gray water being pumped or drained over-
board. Be sure to check all local, state and
federal laws in the boating area.
J - 5

HEADS

A.
Enclosed Head
The.various.anti-pollution.laws.presently.in.effect.have.
necessitated.the.use.and.availability.of.a.wide.variety.
of.heads..The.heads.that.have.been.factory.installed.
in.Four.Winns
.boats.have.been.chosen.to.provide.
®
reasonable.longevity.and.reliable.service,.at.a.realistic.
cost..Refer.to.the.drawings.at.the.end.of.this.section..
Also,.refer.to.the.manufacturers.literature.included.in.
the.owner's.packet.
A fully enclosed fiberglass head is a standard fea-
ture.built.into.the.starboard.console..This.roomy.
head.offers.a.solid.surface.countertop,.vanity,.mirror,.
medicine.cabinet,.sink,.courtesy.light.with.switch,.CO.
monitor, an opening port light, fiberglass liner, porce-
lain.toilet,.storage.locker,.and.overhead.lighting...See.
Figure.J5.
Owner's Manual Page 

Advertisement

Table of Contents
loading

Table of Contents