G. Fire Extinguishing System (Optional)
An automatic FE241 agent fire extinguisher system is
optional on the 310 Horizon™ models.
if.equipped,.is.installed.inside.the.engine.com-
partment..See.Figure.L14.
Figure L14: Optional Fire Extinguishing System
While the system ensures excellent overall bilge fire
protection,.it does not eliminate the USCG require-
ment for hand-held fire extinguishers..Refer.to.the.
extinguisher.manufacturer's.literature.included.in.the.
owner's.packet.if.so.equipped.
H. Inflator (Optional)
With.the huge.rise.in popularity.of.tubing.and.
towable.toys,.the.310.Horizon.models.can.be.
equipped with an optional inflator. This inflator
allows for the quick inflation of the towable when
your.ready.to.tube..It.is.not.necessary.to.have.to.
inflate the tube and transport it prior to getting to
your tubing site. Simply plug the inflator into the
12 volt receptacle and inflate the towable upon
your arrival. Storage for the inflator is under the
starboard.aft.sunpad.seat.cushion..See.Figure.
L15.
Inflator
Figure L15: Optional Inflator
Interior Equipment - Section L
The.system,.
12 Volt
Receptacle
L - 3
AIR CONDITIONING (Optional)
The.optional.air.conditioner.provides.cooling.to.the.
day.berth..The.unit.operates.on.120.volt.AC.power.
thus.the.dockside.power.option.is.required..If.the.
generator.option.is.installed,.this.too.can.supply.power.
to.the.air.conditioner..The.output.of.the.air.conditioner.
may.be.found.on.our.website.at.www.fourwinns.com..
The.air.conditioning.breaker.must.be.turned.on.to.
activate.the.air.conditioning.unit.when.connected.to.
shore.power.or.with.an.optional.generator.operating..
This.breaker.is.located.on.the.AC.panel..Depending.
upon.humidity,.the.air.conditioner.will.condense.
approximately.5.to.15.gallons.of.water.a.day.and.this.
water.drains.into.the.sump.pump..
The seawater inlet valve (seacock) is identified with a
plate.inscribed.with.the.words."Air.Conditioner.Seawa-
ter". Access to the seacock is gained through engine
compartment.
NOTICE
In order to use the air conditioner, you must
first open the seawater inlet valve - seacock
(handle parallel to the flow of valve). When not
using the air conditioner be sure to close the
valve/seacock.
If.equipped,.please.read.the.manufacturer's.informa-
tion.on.the.air.conditioner.contained.in.the.owner's.
packet.for.operation.instructions.
NOTICE
Most air conditioners utilize surface water as
the cooling medium. Prior to using the air
conditioning, the boat must be in the water and
the seacock to the air conditioning water intake
must be in the open position. Operating air
conditioners without proper cooling water will
cause damage to the air conditioning system.
Clean.the.sea.water.strainer.often..Also,.clean.the.
return air filter screens, located behind the louvered
grills,.at.least.once.a.month.
To.winterize,.refer.to.the.manufacturer's.literature.
included.in.the.owner's.packet.